Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Preferred Reporting Items for Diagnostic Accuracy Studies in Endodontics (PRIDASE) guidelines: a development protocol

Nagendrababu, V., Abbott, P., Duncan, H. F., Fouad, A. F., Kruse, C., Patel, S., Pigg, M., Rechenberg, D. K. and Dummer, P. M. H. ORCID: https://orcid.org/0000-0002-0726-7467 2021. Preferred Reporting Items for Diagnostic Accuracy Studies in Endodontics (PRIDASE) guidelines: a development protocol. International Endodontic Journal 54 (7) , pp. 1051-1055. 10.1111/iej.13497

[thumbnail of PRIDASE.pdf] PDF - Accepted Post-Print Version
Download (202kB)

Abstract

Diagnostic accuracy studies play an important role in informing clinical practice and patient management, by evaluating the ability of diagnostic testing and imaging to identify the presence or absence of a disease or condition. These studies compare the relative diagnostic strength of the test or device with a reference standard, therefore, guiding clinical decisions on the reliability of the test, the need for further tests, and whether to monitor or treat a particular condition. Inadequate and incomplete reporting of diagnostic accuracy studies can disguise methodological deficiencies and ultimately result in study bias and the inability to translate research findings into daily clinical practice. The Preferred Reporting Items for Diagnostic Accuracy Studies in Endodontics (PRIDASE) guidelines are being developed in order to improve the accuracy, transparency, completeness and reproducibility of diagnostic accuracy studies in the speciality of Endodontology. The aim of this paper is to report the process used to develop the PRIDASE guidelines based on a well‐established consensus process. The project leaders (PD, VN) formed a steering committee of nine members (PD, VN, PA, AF, DR, SP, CK, MP, HD) to oversee and manage the project. The PRIDASE steering committee will develop the initial draft of the PRIDASE guidelines by adapting and modifying the Standards for Reporting of Diagnostic Accuracy Studies (STARD) 2015 guidelines, adding new items related specifically to the nature of Endodontics and incorporate the Clinical and Laboratory Images in Publication (CLIP) principles. The initial guidelines will consist of a series of domains and individual items and will be validated by the members of a PRIDASE Delphi Group (PDG) consisting of a minimum of 30 individuals who will evaluate independently the individual items based on two parameters: ‘clarity’ using a dichotomous scoring (yes/no) and ‘suitability’ for inclusion using a 9‐point Likert Scale. The scores awarded by each member and any suggestions for improvement will be shared with the PDG to inform an iterative process that will result in a series of items that are clear and suitable for inclusion in the new PRIDASE guidelines. Once the PDG has completed its work, the steering committee will create a PRIDASE Meeting Group (PMG) of 20 individuals from around the world. Members of the PDG will be eligible to be the part of PMG. The draft guidelines and flowchart approved by the PDG will then be presented for further validation and agreement by the PMG. As a result of these discussions, the PRIDASE guidelines will be finalized and then disseminated to relevant stakeholders through publications and via the Preferred Reporting Items for study Designs in Endodontology (PRIDE) website (http://pride‐endodonticguidelines.org). Periodic updates to the PRIDASE guidelines will be made based on feedback from stakeholders and end‐users.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Dentistry
Publisher: Wiley
ISSN: 0143-2885
Date of First Compliant Deposit: 15 March 2021
Date of Acceptance: 11 February 2021
Last Modified: 08 May 2023 16:56
URI: https://orca.cardiff.ac.uk/id/eprint/139789

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics