Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Adverse hemodynamic effects and echocardiographic consequences of pericardial closure soon after sternotomy and pericardiotomy

Angelini, G. D., Fraser, Alan Gordon, Koning, M. M., Smyllie, J. H., Hop, W. C., Sutherland, G. R. and Verdouw, P. D. 1990. Adverse hemodynamic effects and echocardiographic consequences of pericardial closure soon after sternotomy and pericardiotomy. Circulation 82 (5 Supp) , IV397-406.

Full text not available from this repository.

Abstract

The acute hemodynamic and echocardiographic effects of pericardial closure on cardiac function were studied in 11 pigs during steady-state anesthesia and ventilation. Observations were made after sternotomy, both while the pericardium was open and after it had been closed, and then after closure of the chest, after the pericardium had been reopened by removing the pericardial suture through the chest wall. In five pigs, further observations were made when a suture was tightened to close the pericardium while the chest remained closed. Closure of the pericardium when the chest was open reduced cardiac output by 14% and mean stroke volume by 19% (both p less than 0.05). Systemic vascular resistance increased by 15% when the pericardium was closed while the chest was open (NS), and increased by 19% when it was closed while the chest was closed (p less than 0.05). Heart rate did not change significantly, and the systemic blood pressure was maintained (-8%, NS). All these effects were reversed by opening the pericardium. Intrathoracic epicardial echocardiographic monitoring of the left ventricle showed that its end-diastolic dimension increased (by 11%, p less than 0.05) when the pericardium was opened. After chest closure, paradoxical motion of the interventricular septum was consistently demonstrated only during ventilation, and it was not related to whether or not the pericardium was open. This study suggests that cardiac function may be impaired by pericardial closure after cardiac surgery because of some degree of constriction of the heart chambers, although acute circulatory responses compensate for the mild decrease in stroke volume. Monitoring of blood pressure alone cannot document the subtle circulatory changes induced by pericardial closure, and therefore it is not a reliable guide to decisions of whether to close the pericardium or leave it open in individual patients.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Medicine
Subjects: R Medicine > R Medicine (General)
R Medicine > RZ Other systems of medicine
Publisher: American Heart Association
ISSN: 0009-7322
Last Modified: 04 Jun 2017 07:50
URI: https://orca.cardiff.ac.uk/id/eprint/68631

Citation Data

Cited 24 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item