Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Degree-day based non-domestic building energy analytics and modelling should use building and type specific base temperatures

Meng, Qinglong and Mourshed, Monjur ORCID: https://orcid.org/0000-0001-8347-1366 2017. Degree-day based non-domestic building energy analytics and modelling should use building and type specific base temperatures. Energy and Buildings 155 , pp. 260-268. 10.1016/j.enbuild.2017.09.034

[thumbnail of PUBMeng-Mourshed-2017.pdf]
Preview
PDF - Published Version
Available under License Creative Commons Attribution Non-commercial No Derivatives.

Download (2MB) | Preview

Abstract

A deeper understanding of building performance is essential to reduce their energy consumption and corresponding greenhouse gas emissions. Heating degree-days (HDD) encapsulates the severity and duration of cold weather, which is routinely used for weather related analysis of fuel consumption, performance benchmarking, and compliance. The accuracy of HDD-based prediction largely depends on the correct base temperature, which varies depending on building thermal characteristics, and their operation and occupancy. We analysed four years’ (2012-2016) half-hourly metered gas consumption from 119 non-domestic buildings representing seven types, to: (a) identify their base temperature using a three-parameter change point (3PH) regression model, and (b) their relationships with intrinsic building parameters. The highest mean base temperature, 17.7°C was found for clubs and community centres, and the lowest, 12.8°C was for storage buildings. The average of all base temperatures is 16.7°C, which is 1.2°C higher and 1.6°C lower than the British (15.5°C) and American (18.3°C) standards respectively. The current practice of a fixed base temperature degree-days for all buildings has been found to be unrealistic. Building type specific base temperatures must be developed, agreed upon and published for increasing accuracy in energy analytics and legislative compliance, as well as for developing effective standards and policies.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Engineering
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Publisher: Elsevier
ISSN: 0378-7788
Funders: China Scholarship Council, European Commission Horizon 2020
Related URLs:
Date of First Compliant Deposit: 14 September 2017
Date of Acceptance: 13 September 2017
Last Modified: 05 May 2023 12:17
URI: https://orca.cardiff.ac.uk/id/eprint/104675

Citation Data

Cited 19 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics