Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Effect of image registration on 3D absorbed dose calculations in 177 Lu-DOTATOC Peptide Receptor Radionuclide Therapy

Grassi, Elisa, Fioroni, Federica, Berenato, Salvatore, Patterson, Nick, Ferri, Valentina, Braglia, Luca, Filice, Angelina, Versari, Annibale, Iori, Mauro and Spezi, Emiliano ORCID: https://orcid.org/0000-0002-1452-8813 2018. Effect of image registration on 3D absorbed dose calculations in 177 Lu-DOTATOC Peptide Receptor Radionuclide Therapy. Physica Medica: European Journal of Medical Physics 45 , pp. 177-185. 10.1016/j.ejmp.2017.11.021

[thumbnail of manuscript_PhysMe_revised_15102017_final_SB.pdf]
Preview
PDF - Accepted Post-Print Version
Download (581kB) | Preview

Abstract

Peptide receptor radionuclide therapy (PRRT) is an effective MRT (molecular radiotherapy) treatment, which consists of multiple administrations of a radiopharmaceutical labelled with 177Lu or 90Y. Through sequential functional imaging a patient specific 3D dosimetry can be derived. Multiple scans should be previously co-registered to allow accurate absorbed dose calculations. The purpose of this study is to evaluate the impact of image registration algorithms on 3D absorbed dose calculation. A cohort of patients was extracted from the database of a clinical trial in PRRT. They were administered with a single administration of 177Lu-DOTATOC. All patients underwent 5 SPECT/CT sequential scans at 1 h, 4 h, 24 h, 40 h, 70 h post-injection that were subsequently registered using rigid and deformable algorithms. A similarity index was calculated to compare rigid and deformable registration algorithms. 3D absorbed dose calculation was carried out with the Raydose Monte Carlo code. The similarity analysis demonstrated the superiority of the deformable registrations (p < .001). Average absorbed dose to the kidneys calculated using rigid image registration was consistently lower than the average absorbed dose calculated using the deformable algorithm (90% of cases), with percentage differences in the range [−19; +4]%. Absorbed dose to lesions were also consistently lower (90% of cases) when calculated with rigid image registration with absorbed dose differences in the range [−67.2; 100.7]%. Deformable image registration had a significant role in calculating 3D absorbed dose to organs or lesions with volumes smaller than 100 mL. Image based 3D dosimetry for 177Lu-DOTATOC PRRT is significantly affected by the type of algorithm used to register sequential SPECT/CT scans.

Item Type: Article
Date Type: Published Online
Status: Published
Schools: Engineering
Publisher: Fabrizio Serra Editore
Funders: European Metrology Research Programme EURAMET
Date of First Compliant Deposit: 27 November 2017
Date of Acceptance: 26 November 2017
Last Modified: 06 Nov 2023 18:36
URI: https://orca.cardiff.ac.uk/id/eprint/107094

Citation Data

Cited 8 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics