Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Distal fibula oblique fracture fixation using one-third tubular plate with and without lag screw ? A biomechanical study of stability

Manoharan, Gopikanthan, Singh, Rohit, Kuiper, Jan Herman and Nokes, Leonard Derek Martin ORCID: https://orcid.org/0000-0002-9504-8028 2018. Distal fibula oblique fracture fixation using one-third tubular plate with and without lag screw ? A biomechanical study of stability. Journal of Orthopaedics 15 (2) , pp. 549-552. 10.1016/j.jor.2018.05.011

Full text not available from this repository.

Abstract

This laboratory-based study compared distal fibula simple oblique fracture fixation with one-third tubular plate with and without a single lag screw to determine which was mechanically more stable. A control group fixed with a limited contact dynamic compression plate was also tested. Biomechanical testing of 30 osteotomised saw bones under lateral bending and torsional forces was performed. There was no significant difference between the mean lateral bending and mean torsional stiffness between the fixation with tubular plate and lag screw and tubular plate alone. Limited contact dynamic compression plate conferred the best stability in lateral bending and torsion, as expected.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Engineering
Publisher: Elsevier
ISSN: 0972-978X
Date of Acceptance: 6 May 2018
Last Modified: 25 Oct 2022 13:39
URI: https://orca.cardiff.ac.uk/id/eprint/120428

Citation Data

Cited 3 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item