Data-driven respiratory gating outperforms device-based gating for clinical 18F-FDG PET/CT

Walker, Matthew D., Morgan, Andrew J., Bradley, Kevin M. ORCID: https://orcid.org/0000-0003-1911-3382 and McGowan, Daniel R. 2020. Data-driven respiratory gating outperforms device-based gating for clinical 18F-FDG PET/CT. Journal of Nuclear Medicine 61 (11) , pp. 1678-1683. 10.2967/jnumed.120.242248

Full text not available from this repository.

Abstract

A data-driven method for respiratory gating in PET has recently been commercially developed. We sought to compare the performance of the algorithm with an external, device-based system for oncologic 18F-FDG PET/CT imaging. Methods: In total, 144 whole-body 18F-FDG PET/CT examinations were acquired, with a respiratory gating waveform recorded by an external, device-based respiratory gating system. In each examination, 2 of the bed positions covering the liver and lung bases were acquired with a duration of 6 min. Quiescent-period gating retaining approximately 50% of coincidences was then able to produce images with an effective duration of 3 min for these 2 bed positions, matching the other bed positions. For each examination, 4 reconstructions were performed and compared: data-driven gating (DDG) (we use the term DDG-retro to distinguish that we did not use the real-time R-threshold–based application of DDG that is available within the manufacturer’s product), external device-based gating (real-time position management (RPM)–gated), no gating but using only the first 3 min of data (ungated-matched), and no gating retaining all coincidences (ungated-full). Lesions in the images were quantified and image quality scored by a radiologist who was masked to the method of data processing. Results: Compared with the other reconstruction options, DDG-retro increased the SUVmax and decreased the threshold-defined lesion volume. Compared with RPM-gated, DDG-retro gave an average increase in SUVmax of 0.66 ± 0.1 g/mL (n = 87, P < 0.0005). Although the results from the masked image evaluation were most commonly equivalent, DDG-retro was preferred over RPM-gated in 13% of examinations, whereas the opposite occurred in just 2% of examinations. This was a significant preference for DDG-retro (P = 0.008, n = 121). Liver lesions were identified in 23 examinations. Considering this subset of data, DDG-retro was ranked superior to ungated-full in 6 of 23 (26%) cases. Gated reconstruction using the external device failed in 16% of examinations, whereas DDG-retro always provided a clinically acceptable image. Conclusion: In this clinical evaluation, DDG-retro provided performance superior to that of the external device-based system. For most examinations the performance was equivalent, but DDG-retro had superior performance in 13% of examinations, leading to a significant preference overall.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Medicine
Publisher: Society of Nuclear Medicine
ISSN: 0161-5505
Date of Acceptance: 16 March 2020
Last Modified: 09 Nov 2022 10:18
URI: https://orca.cardiff.ac.uk/id/eprint/139023

Citation Data

Cited 22 times in Scopus. View in Scopus. Powered By Scopus® Data