Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Different fuzzy control configurations tuned by the Bees Algorithm for LFC of two-area power system

Shouran, Mokhtar ORCID: https://orcid.org/0000-0002-9904-434X, Anayi, Fatih ORCID: https://orcid.org/0000-0001-8408-7673, Packianather, Michael ORCID: https://orcid.org/0000-0002-9436-8206 and Habil, Monier 2022. Different fuzzy control configurations tuned by the Bees Algorithm for LFC of two-area power system. Energies 15 (2) , 657. 10.3390/en15020657

[thumbnail of energies-15-00657-v2.pdf] PDF - Published Version
Available under License Creative Commons Attribution.

Download (11MB)

Abstract

This study develops and implements a design of the Fuzzy Proportional Integral Derivative with filtered derivative mode (Fuzzy PIDF) for Load Frequency Control (LFC) of a two-area interconnected power system. To attain the optimal values of the proposed structure’s parameters which guarantee the best possible performance, the Bees Algorithm (BA) and other optimisation tools are used to accomplish this task. A Step Load Perturbation (SLP) of 0.2 pu is applied in area one to examine the dynamic performance of the system with the proposed controller employed as the LFC system. The supremacy of Fuzzy PIDF is proven by comparing the results with those of previous studies for the same power system. As the designed controller is required to provide reliable performance, this study is further extended to propose three different fuzzy control configurations that offer higher reliability, namely Fuzzy Cascade PI − PD, Fuzzy PI plus Fuzzy PD, and Fuzzy (PI + PD), optimized by the BA for the LFC for the same dual-area power system. Moreover, an extensive examination of the robustness of these structures towards the parametric uncertainties of the investigated power system, considering thirteen cases, is carried out. The simulation results indicate that the contribution of the BA tuned the proposed fuzzy control structures in alleviating the overshoot, undershoot, and the settling time of the frequency in both areas and the tie-line power oscillations. Based on the obtained results, it is revealed that the lowest drop of the frequency in area one is −0.0414 Hz, which is achieved by the proposed Fuzzy PIDF tuned by the BA. It is also divulged that the proposed techniques, as was evidenced by their performance, offer a good transient response, a considerable capability for disturbance rejection, and an insensitivity towards the parametric uncertainty of the controlled system.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Engineering
Additional Information: This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/).
Publisher: MDPI
ISSN: 1996-1073
Date of First Compliant Deposit: 2 February 2022
Date of Acceptance: 14 January 2022
Last Modified: 10 Feb 2024 02:09
URI: https://orca.cardiff.ac.uk/id/eprint/147000

Citation Data

Cited 13 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics