Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Analysis of a basement fault zone with geothermal potential in the Southern North Sea

Alves, Tiago M. ORCID: https://orcid.org/0000-0002-2765-3760, Mattos, Nathalia H., Newnes, Sarah and Goodall, Sinéad 2022. Analysis of a basement fault zone with geothermal potential in the Southern North Sea. Geothermics 102 , 102398. 10.1016/j.geothermics.2022.102398

[thumbnail of TA_1-s2.0-S0375650522000505-main.pdf]
Preview
PDF - Published Version
Available under License Creative Commons Attribution.

Download (37MB) | Preview
License URL: http://creativecommons.org/licenses/by/4.0/
License Start date: 14 March 2022

Abstract

Extraordinary 3D seismic data from the Central Offshore Platform (Southern North Sea), complemented by information from 38 boreholes, reveal a 10 km-wide basement fault zone above which fluid anomalies emanate from sub-salt reservoirs to terminate in lower Cretaceous strata. Fluid blow-out pipes, chimneys and low-amplitude trails were mostly sourced from the region where NW-striking syn-rift faults intersect the N-striking basement fault zone. As a result, 73% of the mapped fluid-flow anomalies (94 out of 129) occur within the basement fault zone of interest or follow a N-S strike along its shoulders. We postulate a strong control of the basement fault zone on past fluid and heat flow, as basin models confirm that fluid and heat were mostly produced during the Cretaceous. Bottom-hole data record temperatures of ∼140 °C at present, highlighting the geothermal potential of the study area. These temperatures nevertheless contrast with the relatively constant gradient of ∼ 32 °C/km occurring both in and outside the basement fault zone. This work is important as its shows that past fluid and heat flow over a basement fault zone does not necessarily correlate with the existence of an enhanced hydrothermal system at present. However, as bottom-hole temperatures are within the benchmark values considered across Europe, it also stresses the importance of basement fault zones as key structures to find, and assess, as potential geothermal sites.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Earth and Environmental Sciences
Additional Information: This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)
Publisher: Elsevier
ISSN: 0375-6505
Funders: EPSRC
Date of First Compliant Deposit: 13 April 2022
Date of Acceptance: 5 March 2022
Last Modified: 22 May 2023 21:43
URI: https://orca.cardiff.ac.uk/id/eprint/149171

Citation Data

Cited 4 times in Scopus. View in Scopus. Powered By Scopus® Data