Abstract

In the fight against climate change, energy modeling is a key tool used to analyze the performance of proposed energy conservation measures for buildings. Studies on the integration of photovoltaic energy in buildings must use calibrated building energy models, as only with them is the demand curve real, and the savings obtained at the self-consumption level, energy storage in the building, or feed into the grid are accurate. The adjustment process of a calibrated model depends on aspects inherent to the building properties (envelope parameters, internal loads, use schedules) as well as external to them (weather, ground properties, etc.). Naturally, the uncertainty of each is essential to obtaining good results. As for the meteorological data, it is preferable to use data from a weather station located in the building or its surroundings, although this is not always possible due to the cost of the initial investment and its maintenance. As a result, weather stations with public access to their data, such as those located at airports or specific locations in cities, are largely used to perform calibrations of building energy models, making it challenging to converge the simulated model with measured data. This research sheds light on how this obstacle can be overcome by using weather data provided by a third-party company, bridging the gap between reality and energy models. For this purpose, calibrations of the two buildings proposed in Annex 58 were performed with different weather configurations, using the mean absolute error (MAE) uncertainty index and Spearman’s rank correlation coefficient (rho) as comparative measures. An optimal and cost-effective solution was found as an alternative to an on-site weather station, based on the use of a single outdoor temperature sensor in combination with third-party weather data, achieving a robust and reliable building energy model.

Item Type: Article
Date Type: Published Online
Status: Published
Schools: Architecture
Additional Information: License information from Publisher: LICENSE 1: URL: https://creativecommons.org/licenses/by/4.0/
Publisher: MDPI
Date of First Compliant Deposit: 25 July 2022
Date of Acceptance: 19 July 2022
Last Modified: 07 May 2023 19:16
URI: https://orca.cardiff.ac.uk/id/eprint/151452

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics