Health and economic benefits of building ventilation interventions for reducing indoor PM2.5 exposure from both indoor and outdoor origins in urban Beijing, China

Yuan, Ye, Luo, Zhiwen ORCID: https://orcid.org/0000-0002-2082-3958, Liu, Jing, Wang, Yaowu and Lin, Yaoyu 2018. Health and economic benefits of building ventilation interventions for reducing indoor PM2.5 exposure from both indoor and outdoor origins in urban Beijing, China. Science of the Total Environment 626 , pp. 546-554. 10.1016/j.scitotenv.2018.01.119

Full text not available from this repository.

Abstract

China is confronted with serious PM2.5 pollution, especially in the capital city of Beijing. Exposure to PM2.5 could lead to various negative health impacts including premature mortality. As people spend most of their time indoors, the indoor exposure to PM2.5 from both indoor and outdoor origins constitutes the majority of personal exposure to PM2.5 pollution. Different building interventions have been introduced to mitigate indoor PM2.5 exposure, but always at the cost of energy expenditure. In this study, the health and economic benefits of different ventilation intervention strategies for reducing indoor PM2.5 exposure are modeled using a representative urban residence in Beijing, with consideration of different indoor PM2.5 emission strengths and outdoor pollution. Our modeling results show that the increase of envelope air-tightness can achieve significant economic benefits when indoor PM2.5 emissions are absent; however, if an indoor PM2.5 source is present, the benefits only increase slightly in mechanically ventilated buildings, but may show negative benefit without mechanical ventilation. Installing mechanical ventilation in Beijing can achieve annual economic benefits ranging from 200yuan/capita to 800yuan/capita if indoor PM2.5 sources exist. If there is no indoor emission, the annual benefits above 200yuan/capita can be achieved only when the PM2.5 filtration efficiency is no <90% and the envelope air-tightness is above Chinese National Standard Level 7. Introducing mechanical ventilation with low PM2.5 filtration efficiency to current residences in urban Beijing will increase the indoor PM2.5 exposure and result in excess costs to the residents.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Architecture
Publisher: Elsevier
ISSN: 0048-9697
Date of Acceptance: 12 January 2018
Last Modified: 10 Nov 2022 11:44
URI: https://orca.cardiff.ac.uk/id/eprint/151652

Citation Data

Cited 31 times in Scopus. View in Scopus. Powered By Scopus® Data