Hang, Jian, Chen, Xieyuan, Chen, Guanwen, Chen, Taihan, Lin, Yuanyuan, Luo, Zhiwen ORCID: https://orcid.org/0000-0002-2082-3958, Zhang, Xuelin and Wang, Qun 2020. The influence of aspect ratios and wall heating conditions on flow and passive pollutant exposure in 2D typical street canyons. Building and Environment 168 , 106536. 10.1016/j.buildenv.2019.106536 |
Abstract
Deep street canyons and unfavourable meteorological conditions usually induce high pollutant exposure. Validated by experimental data, this paper employs computational fluid dynamic simulations with RNG k-ε model to investigate the flow, and passive pollutant dispersion within scale-model two-dimensional street canyons(H = 3 m). As a novelty, this paper quantifies the impacts of various wall heating scenarios(bottom, leeward/windward wall and all-wall heating), ambient velocity(Uref = 0.5–2 m s−1, Froude numbers Fr = 0.25–4.08, Reynolds numbers Re = 95602–382409) and aspect ratios(building height/street width, AR = 0.5, 0.67, 1, 2, 3) on personal intake fraction for entire streets(). The governing equations are implicitly discretized by a finite volume method (FVM) and the second-order upwind scheme with Boussinesq model for quantifying buoyancy effects. The SIMPLE scheme is adopted for the pressure and velocity coupling. In most isothermal cases, one-main-vortex structure exists as AR = 0.5–3( = 0.43–3.96 ppm and 1.66–27.51 ppm with Uref = 2 and 0.5 m s−1). For non-isothermal cases with Fr = 4.08(Uref = 2 m s−1), wind-driven force dominates urban airflow as AR = 0.5–1 and four heating conditions attain similar (0.39–0.43 ppm, 0.57–0.60 ppm, 0.91–0.98 ppm). As AR = 2, windward and all-wall heating get two-vortex structures with greater (3.18–3.33 ppm) than others( = 2.13–2.21 ppm). As AR = 3, leeward-wall heating slightly reduces (~3.72–3.96 ppm), but the other three produce two-vortex structures with greater (6.13–10.32 ppm). As Fr = 0.25(Uref = 0.5 m s−1), leeward-wall heating always attains smaller (1.20–7.10 ppm) than isothermal cases(1.66–27.51 ppm) as AR = 0.5–3, however the influence of the other three is complicated which sometimes raises or reduces . Overall, smaller background wind speed (Fr = 0.25) with two-vortex structures attains much larger . Special attention is required at night(all-wall heating), noon(bottom-heating) and cloudy period(no-wall heating) as AR = 2–3, while it is during windward-wall heating and cloudy period for AR = 0.5–1.
Item Type: | Article |
---|---|
Date Type: | Publication |
Status: | Published |
Schools: | Architecture |
Publisher: | Elsevier |
ISSN: | 0360-1323 |
Date of Acceptance: | 5 November 2019 |
Last Modified: | 10 Nov 2022 11:45 |
URI: | https://orca.cardiff.ac.uk/id/eprint/151757 |
Citation Data
Cited 29 times in Scopus. View in Scopus. Powered By Scopus® Data
Actions (repository staff only)
Edit Item |