Role of pathogen-laden expiratory droplet dispersion and natural ventilation explaining a COVID-19 outbreak in a coach bus

Luo, Q., Ou, C., Hang, J., Luo, Z. ORCID: https://orcid.org/0000-0002-2082-3958, Yang, H., Yang, X., Zhang, X., Li, Y. and Fan, X. 2022. Role of pathogen-laden expiratory droplet dispersion and natural ventilation explaining a COVID-19 outbreak in a coach bus. Building and Environment 220 , 109160. 10.1016/j.buildenv.2022.109160

Full text not available from this repository.

Abstract

The influencing mechanism of droplet transmissions inside crowded and poorly ventilated buses on infection risks of respiratory diseases is still unclear. Based on experiments of one-infecting-seven COVID-19 outbreak with an index patient at bus rear, we conducted CFD simulations to investigate integrated effects of initial droplet diameters(tracer gas, 5 μm, 50 μm and 100 μm), natural air change rates per hour(ACH = 0.62, 2.27 and 5.66 h−1 related to bus speeds) and relative humidity(RH = 35% and 95%) on pathogen-laden droplet dispersion and infection risks. Outdoor pressure difference around bus surfaces introduces natural ventilation airflow entering from bus-rear skylight and leaving from the front one. When ACH = 0.62 h−1(idling state), the 30-min-exposure infection risk(TIR) of tracer gas is 15.3%(bus rear) - 11.1%(bus front), and decreases to 3.1%(bus rear)-1.3%(bus front) under ACH = 5.66 h−1(high bus speed).The TIR of large droplets(i.e., 100 μm/50 μm) is almost independent of ACH, with a peak value(∼3.1%) near the index patient, because over 99.5%/97.0% of droplets deposit locally due to gravity. Moreover, 5 μm droplets can disperse further with the increasing ventilation. However, TIR for 5 μm droplets at ACH = 5.66 h−1 stays relatively small for rear passengers(maximum 0.4%), and is even smaller in the bus middle and front(<0.1%). This study verifies that differing from general rooms, most 5 μm droplets deposit on the route through the long-and-narrow bus space with large-area surfaces(L∼11.4 m). Therefore, tracer gas can only simulate fine droplet with little deposition but cannot replace 5–100 μm droplet dispersion in coach buses.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Architecture
Publisher: Elsevier
ISSN: 0360-1323
Date of Acceptance: 30 April 2022
Last Modified: 10 Nov 2022 11:46
URI: https://orca.cardiff.ac.uk/id/eprint/151766