Suliman, Fouad, Anayi, Fatih ![]() ![]() |
Abstract
An appropriate circuit model using a Bees Algorithm (BA) for predicting and evaluating photovoltaic (PV) module performance is developed. The BA simulation model is capable of computing the electrical parameters which are usually not supplied by manufacturers' datasheets with commercial PV modules. BA is employed here for the identification of optimum parameters of the PV module (photo-watt PWP201) for both single diode (SD), and double diode (DD) models. The photovoltaic module is tested using a standard PV characterization system to acquire current-voltage curves. Additionally, b experimental results from the I- V characteristic curves are used as the input parameters for the simulation. The results show that the simulation model can significantly reduce root mean square error of photovoltaic modules between the measured and calculated data. A comparative study of the simulation technique and other techniques from the literature demonstrates the functionality and applicability of the BA for PV systems. The novel technique also presents a promising feature for detecting faults which could be crucial for condition monitoring and fault diagnosis in future PV energy systems.
Item Type: | Conference or Workshop Item (Paper) |
---|---|
Date Type: | Published Online |
Status: | Published |
Schools: | Engineering |
Publisher: | IEEE |
Last Modified: | 28 Dec 2024 15:47 |
URI: | https://orca.cardiff.ac.uk/id/eprint/152045 |
Citation Data
Cited 1 time in Scopus. View in Scopus. Powered By Scopus® Data
Actions (repository staff only)
![]() |