Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Influence of conjunctival folds on calculated tear meniscus volume along the lower eyelid

Bandlitz, Stefan, Purslow, Christine, Murphy, Paul J. and Pult, Heiko ORCID: https://orcid.org/0000-0003-4371-8007 2016. Influence of conjunctival folds on calculated tear meniscus volume along the lower eyelid. The Ocular Surface 14 (3) , pp. 377-384. 10.1016/j.jtos.2016.04.001

Full text not available from this repository.

Abstract

Purpose In calculating tear meniscus volume (TMV), tear meniscus height (TMH), radius (TMR) and cross-sectional area (TMA) are usually measured at the center of the lower lid margin, but lid-parallel conjunctival folds (LIPCOFs) are known to influence the tear meniscus regularity. The aim of this study was to analyze the influence of LIPCOFs on TMA measured by optical coherence tomography (OCT) and consequently, the calculated tear meniscus volume (TMV). Methods Using OCT (Cirrus-HD; Carl Zeiss Meditec, Jena, Germany), the TMH, TMR and TMA in 42 subjects (13M, 29F; mean age 27.3 SD±8.4 years) were measured directly below the pupil center, plus at temporal and nasal locations perpendicularly below the limbus, where LIPCOFs were also evaluated and graded. TMV for the different locations was calculated. Correlations between LIPCOFs and the tear meniscus parameters were analyzed using the Spearman Rank-Order coefficients. Differences between tear meniscus parameters at the different locations were evaluated by the paired t-test. Results Central TMV (5.30±1.42 x10−2μl/mm) was significantly positively correlated to LIPCOF sum (grade 2.4±1.2) (r=0.422; P<.05). The calculated temporal TMV was greater by 0.53x10−2μl/mm compared to the central TMV (P=.037), while there was no significant difference in tear volume between the other locations. Conclusions Using OCT it was possible to investigate the influence of LIPCOFs on TMH, TMR, and for the first time on TMA, at central and paracentral positions along the lower lid margin. The presence of LICPOF results in an irregularity of tear meniscus with a difference in the amount of predicted tear volume while measuring TMH or TMR at the different locations.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Schools > Optometry and Vision Sciences
Publisher: Elsevier
ISSN: 1542-0124
Date of Acceptance: 1 April 2016
Last Modified: 01 Dec 2023 11:00
URI: https://orca.cardiff.ac.uk/id/eprint/164140

Actions (repository staff only)

Edit Item Edit Item