Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Validation of artificial intelligence-based digital microscopy for automated detection of Schistosoma haematobium eggs in urine in Gabon

Meulah, Brice, Oyibo, Prosper, Hoekstra, Pytsje T., Moure, Paul Alvyn Nguema, Maloum, Moustapha Nzamba, Laclong-Lontchi, Romeo Aime, Honkpehedji, Yabo Josiane, Bengtson, Michel, Hokke, Cornelis, Corstjens, Paul L. A. M., Agbana, Temitope, Diehl, Jan Carel, Adegnika, Ayola Akim and van Lieshout, Lisette 2024. Validation of artificial intelligence-based digital microscopy for automated detection of Schistosoma haematobium eggs in urine in Gabon. PLoS Neglected Tropical Diseases 18 (2) , e0011967. 10.1371/journal.pntd.0011967

[thumbnail of journal.pntd.0011967.pdf] PDF - Published Version
Available under License Creative Commons Attribution.

Download (1MB)

Abstract

Introduction Schistosomiasis is a significant public health concern, especially in Sub-Saharan Africa. Conventional microscopy is the standard diagnostic method in resource-limited settings, but with limitations, such as the need for expert microscopists. An automated digital microscope with artificial intelligence (Schistoscope), offers a potential solution. This field study aimed to validate the diagnostic performance of the Schistoscope for detecting and quantifying Schistosoma haematobium eggs in urine compared to conventional microscopy and to a composite reference standard (CRS) consisting of real-time PCR and the up-converting particle (UCP) lateral flow (LF) test for the detection of schistosome circulating anodic antigen (CAA). Methods Based on a non-inferiority concept, the Schistoscope was evaluated in two parts: study A, consisting of 339 freshly collected urine samples and study B, consisting of 798 fresh urine samples that were also banked as slides for analysis with the Schistoscope. In both studies, the Schistoscope, conventional microscopy, real-time PCR and UCP-LF CAA were performed and samples with all the diagnostic test results were included in the analysis. All diagnostic procedures were performed in a laboratory located in a rural area of Gabon, endemic for S. haematobium. Results In study A and B, the Schistoscope demonstrated a sensitivity of 83.1% and 96.3% compared to conventional microscopy, and 62.9% and 78.0% compared to the CRS. The sensitivity of conventional microscopy in study A and B compared to the CRS was 61.9% and 75.2%, respectively, comparable to the Schistoscope. The specificity of the Schistoscope in study A (78.8%) was significantly lower than that of conventional microscopy (96.4%) based on the CRS but comparable in study B (90.9% and 98.0%, respectively). Conclusion Overall, the performance of the Schistoscope was non-inferior to conventional microscopy with a comparable sensitivity, although the specificity varied. The Schistoscope shows promising diagnostic accuracy, particularly for samples with moderate to higher infection intensities as well as for banked sample slides, highlighting the potential for retrospective analysis in resource-limited settings.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Engineering
Publisher: Public Library of Science
ISSN: 1935-2735
Date of First Compliant Deposit: 19 March 2024
Date of Acceptance: 5 February 2024
Last Modified: 19 Mar 2024 15:30
URI: https://orca.cardiff.ac.uk/id/eprint/166724

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics