Hughes, F. M., Anaya-Lara, O., Ramtharan, G., Jenkins, Nicholas ![]() |
Abstract
The aim of the paper is to demonstrate the way in which mechanical power variations, due to tower shadow and wind turbulence, influence control performance of power system stabilizer (PSS) loops for doubly-fed induction generators (DFIGs). The PSS auxiliary loops are applied on a specific DFIG control scheme, the flux magnitude and angle controller (FMAC). However, since the PSS signal is applied at the output of the basic controller, the PSS performance characteristics displayed are deemed typical for DFIG control schemes in general. The relative capabilities of PSS controllers based on stator power, rotor speed, and network frequency, when the DFIG turbine is subjected to aerodynamic torque variations, are investigated via simulation studies. A two-generator aggregate model of a wind farm is introduced, which enables the influence of tower shadow and wind turbulence on both an individual turbine and on the overall wind farm itself to be assessed.
Item Type: | Article |
---|---|
Date Type: | Publication |
Status: | Published |
Schools: | Engineering |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) T Technology > TD Environmental technology. Sanitary engineering |
Uncontrolled Keywords: | Doubly-fed induction generator (DFIG) control; dynamic stability; power system stabilizer; tower shadow; transient stability |
Publisher: | Institute of Electrical and Electronics Engineers |
ISSN: | 0885-8969 |
Last Modified: | 17 Oct 2022 09:44 |
URI: | https://orca.cardiff.ac.uk/id/eprint/5431 |
Citation Data
Cited 61 times in Scopus. View in Scopus. Powered By Scopus® Data
Actions (repository staff only)
![]() |
Edit Item |