Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Flux calibration of the Herschel-SPIRE photometer

Bendo, G. J., Griffin, Matthew J. ORCID: https://orcid.org/0000-0002-0033-177X, Bock, J. J., Conversi, L., Dowell, C. D., Lim, T., Lu, N., North, Christopher E., Papageorgiou, Andreas, Pearson, C. P., Pohlen, M., Polehampton, E. T., Schulz, B., Shupe, D. L., Sibthorpe, B., Spencer, Locke, Swinyard, B. M., Valtchanov, I. and Xu, C. K. 2013. Flux calibration of the Herschel-SPIRE photometer. Monthly Notices of the Royal Astronomical Society 433 (4) , pp. 3062-3078. 10.1093/mnras/stt948

Full text not available from this repository.

Abstract

We describe the procedure used to flux calibrate the three-band submillimetre photometer in the Spectral and Photometric Imaging Receiver instrument on the Herschel Space Observatory. This includes the equations describing the calibration scheme, a justification for using Neptune as the primary calibration source, a description of the observations and data processing procedures used to derive flux calibration parameters (for converting from voltage to flux density) for every bolometer in each array, an analysis of the error budget in the flux calibration for the individual bolometers and tests of the flux calibration on observations of primary and secondary calibrators. The procedure for deriving the flux calibration parameters is divided into two parts. In the first part, we use observations of astronomical sources in conjunction with the operation of the photometer internal calibration source to derive the unscaled derivatives of the flux calibration curves. To scale the calibration curves in Jy beam−1 V−1, we then use observations of Neptune in which the beam of each bolometer is mapped using a very fine scan pattern. The total instrumental uncertainties in the flux calibration for most individual bolometers is ∼0.5 per cent, although a few bolometers have uncertainties of ∼1–5 per cent because of issues with the Neptune observations. Based on application of the flux calibration parameters to Neptune observations performed using typical scan map observing modes, we determined that measurements from each array as a whole have instrumental uncertainties of 1.5 per cent. This is considerably less than the absolute calibration uncertainty associated with the model of Neptune, which is estimated at 4 per cent.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Physics and Astronomy
Subjects: Q Science > QC Physics
Publisher: Oxford University Press
ISSN: 0035-8711
Funders: UKSA, STFC
Last Modified: 25 Oct 2022 09:28
URI: https://orca.cardiff.ac.uk/id/eprint/58680

Citation Data

Cited 110 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item