Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Real-life step and activity measurement: reliability and validity

Busse, Monica ORCID: https://orcid.org/0000-0002-5331-5909, Van Deursen, Robert William Martin ORCID: https://orcid.org/0000-0002-9461-0111 and Wiles, Charles Mark 2009. Real-life step and activity measurement: reliability and validity. Journal of Medical Engineering & Technology 33 (1) , pp. 33-41. 10.1080/03091900701682606

Full text not available from this repository.

Abstract

Objectives: Investigation of the reliability and validity of activity monitoring using a range of methods, namely manual counting, self report and two commercially available activity monitors. Study design: Reliability, accuracy and validity study. Methods: Multiple convenience samples of healthy subjects were recruited to the study. Reliability of manual step count was determined using an intraclass correlation coefficient (ICC) (n = 10). Relationships between data from the Step Watch™ monitor (SAM) and (a) manual step counts (n = 18); (b) a second (different) activity monitor (ActivPAL); and (c) self reported activity levels (n = 22) were assessed using correlations. A Pearson's correlation and paired t-test was used to assess relations between routinely used monitors. Results: Intra-rater reliability for manual step counts was excellent (ICC 0.99), but inter-rater reliability was poor (ICC 0.26). Indoor accuracy of the SAM was 96.06% and outdoor accuracy was 99.58%. Moderate correlations (rho = 0.423 to 0.595, p < 0.05) were identified between the SAM monitor activity levels and self report diaries. The SAM and the ActivPAL were found to be internally reliable within themselves (ICC 0.96 and 0.95 respectively), significantly correlated (r = 0.93, p < 0.001) but also significantly different (t = 2.179, p < 0.05) when used simultaneously over the same circuit. Conclusions: Activity monitors provide information that is related to actual activity and provide accurate and reliable data when tested on functional walking circuits. Activity monitors should not be used interchangeably due to the potential for systematic differences between the measurements obtained when applied simultaneously over the same repeated circuit.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Medicine
Healthcare Sciences
Subjects: R Medicine > R Medicine (General)
Uncontrolled Keywords: Activity monitoring; Mobility; Activities of daily living; Validity; Reliability
Publisher: Informa Healthcare
ISSN: 03091902
Last Modified: 17 Oct 2022 10:09
URI: https://orca.cardiff.ac.uk/id/eprint/7151

Citation Data

Cited 45 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)