Li, B., Duan, Z., Wang, X. and Wu, Jianzhong ORCID: https://orcid.org/0000-0001-7928-3602 2016. Loss-of-excitation analysis and protection for pumped storage machines during starting. IET Renewable Power Generation 10 (1) , pp. 71-78. 10.1049/iet-rpg.2015.0013 |
Abstract
The reversible synchronous machines in a pumped station are put into operation frequently for effective operation of the hydro pumped-storage system. The detection of loss-of-excitation (LOE), which is a common failure for synchronous machines, must be guaranteed not only in normal operation, but also under starting and other possible operation conditions. A model of pumped-storage units under the starting condition was developed using the SimPowerSystems in Matlab/Simulink. The simulation results and real tests of a pumped-storage power plant in northeast China were presented. The LOE characteristics during starting were analysed for the first time. Since the frequency of voltage and current runs up gradually from zero to the rated frequency during starting, conventional LOE protections based on impedance under the rated frequency have to be disabled during starting. For this reason, a novel LOE protection was developed based on the R–L time-domain model and the least-square algorithm. Theoretical analysis and simulation tests demonstrate that the proposed LOE protection method is correct and valid.
Item Type: | Article |
---|---|
Date Type: | Publication |
Status: | Published |
Schools: | Engineering |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) |
Publisher: | Institution of Engineering and Technology |
ISSN: | 1752-1424 |
Funders: | Engineering and Physical Sciences Research Council |
Date of Acceptance: | 14 July 2015 |
Last Modified: | 28 Oct 2022 09:28 |
URI: | https://orca.cardiff.ac.uk/id/eprint/74632 |
Citation Data
Cited 11 times in Scopus. View in Scopus. Powered By Scopus® Data
Actions (repository staff only)
Edit Item |