Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Discrepancies in reporting the CAG repeat lengths for Huntington's disease

Quarrell, Oliver W, Handley, Olivia, O'Donovan, Kirsty, Dumoulin, Christine, Ramos-Arroyo, Maria, Biunno, Ida, Bauer, Peter, Kline, Margaret, Landwehrmeyer, G Bernhard, Bisson, Jonathan Ian ORCID: https://orcid.org/0000-0001-5170-1243 and Rosser, Anne Elizabeth ORCID: https://orcid.org/0000-0002-4716-4753 2012. Discrepancies in reporting the CAG repeat lengths for Huntington's disease. European Journal of Human Genetics 20 (1) , pp. 20-26. 10.1038/ejhg.2011.136

Full text not available from this repository.

Abstract

Huntington's disease results from a CAG repeat expansion within the Huntingtin gene; this is measured routinely in diagnostic laboratories. The European Huntington's Disease Network REGISTRY project centrally measures CAG repeat lengths on fresh samples; these were compared with the original results from 121 laboratories across 15 countries. We report on 1326 duplicate results; a discrepancy in reporting the upper allele occurred in 51% of cases, this reduced to 13.3% and 9.7% when we applied acceptable measurement errors proposed by the American College of Medical Genetics and the Draft European Best Practice Guidelines, respectively. Duplicate results were available for 1250 lower alleles; discrepancies occurred in 40% of cases. Clinically significant discrepancies occurred in 4.0% of cases with a potential unexplained misdiagnosis rate of 0.3%. There was considerable variation in the discrepancy rate among 10 of the countries participating in this study. Out of 1326 samples, 348 were re-analysed by an accredited diagnostic laboratory, based in Germany, with concordance rates of 93% and 94% for the upper and lower alleles, respectively. This became 100% if the acceptable measurement errors were applied. The central laboratory correctly reported allele sizes for six standard reference samples, blind to the known result. Our study differs from external quality assessment (EQA) schemes in that these are duplicate results obtained from a large sample of patients across the whole diagnostic range. We strongly recommend that laboratories state an error rate for their measurement on the report, participate in EQA schemes and use reference materials regularly to adjust their own internal standards.

Item Type: Article
Date Type: Publication
Status: Published
Schools: MRC Centre for Neuropsychiatric Genetics and Genomics (CNGG)
Medicine
Neuroscience and Mental Health Research Institute (NMHRI)
Subjects: R Medicine > R Medicine (General)
Additional Information: Jonathan Bisson and Anne Rosser are collaborators on this article.
Publisher: Nature Publishing Group
ISSN: 1018-4813
Last Modified: 17 Nov 2022 12:16
URI: https://orca.cardiff.ac.uk/id/eprint/80376

Citation Data

Cited 12 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item