Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Potential pitfalls when denoising resting state fMRI data using nuisance regression

Bright, Molly G., Tench, Christopher R. and Murphy, Kevin ORCID: https://orcid.org/0000-0002-6516-313X 2017. Potential pitfalls when denoising resting state fMRI data using nuisance regression. NeuroImage 154 , pp. 159-168. 10.1016/j.neuroimage.2016.12.027

[thumbnail of 1-s2.0-S1053811916307480-main v2.pdf]
Preview
PDF - Published Version
Available under License Creative Commons Attribution.

Download (1MB) | Preview

Abstract

In resting state fMRI, it is necessary to remove signal variance associated with noise sources, leaving cleaned fMRI time-series that more accurately reflect the underlying intrinsic brain fluctuations of interest. This is commonly achieved through nuisance regression, in which the fit is calculated of a noise model of head motion and physiological processes to the fMRI data in a General Linear Model, and the “cleaned” residuals of this fit are used in further analysis. We examine the statistical assumptions and requirements of the General Linear Model, and whether these are met during nuisance regression of resting state fMRI data. Using toy examples and real data we show how pre-whitening, temporal filtering and temporal shifting of regressors impact model fit. Based on our own observations, existing literature, and statistical theory, we make the following recommendations when employing nuisance regression: pre-whitening should be applied to achieve valid statistical inference of the noise model fit parameters; temporal filtering should be incorporated into the noise model to best account for changes in degrees of freedom; temporal shifting of regressors, although merited, should be achieved via optimisation and validation of a single temporal shift. We encourage all readers to make simple, practical changes to their fMRI denoising pipeline, and to regularly assess the appropriateness of the noise model used. By negotiating the potential pitfalls described in this paper, and by clearly reporting the details of nuisance regression in future manuscripts, we hope that the field will achieve more accurate and precise noise models for cleaning the resting state fMRI time-series.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Physics and Astronomy
Psychology
Cardiff University Brain Research Imaging Centre (CUBRIC)
Publisher: Elsevier
ISSN: 1053-8119
Funders: Wellcome Trust
Date of First Compliant Deposit: 4 January 2017
Date of Acceptance: 10 December 2016
Last Modified: 05 May 2023 11:30
URI: https://orca.cardiff.ac.uk/id/eprint/97155

Citation Data

Cited 55 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics