Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Optimising the quantitative analysis in functional pet brain imaging

Alzamil, Yasser 2019. Optimising the quantitative analysis in functional pet brain imaging. PhD Thesis, Cardiff University.
Item availability restricted.

[thumbnail of 2019AlzamilYZPhD.pdf]
Preview
PDF - Accepted Post-Print Version
Download (27MB) | Preview
[thumbnail of Cardiff University Electronic Publication Form] PDF (Cardiff University Electronic Publication Form) - Supplemental Material
Restricted to Repository staff only

Download (1MB)

Abstract

Patlak analysis techniques based on linear regression are often applied to positron emission tomography (PET) images to estimate a number of physiological parameters. The Patlak equation forms the basis for most extension works regarding graphical analysis of many tracers in quantitative PET measurements. Patlak analysis is primarily used to obtain the rate constant Ki, which represents the tracer transfer rate from plasma to the targeted tissue. One of the most common issues associated with Patlak analysis is the introduction of statistical noise, adopted originally from the images, that affects the slope of the graphical plot, leading to bias, and causes errors in the calculation of the rate constant Ki i. In this thesis, several statistical and noise reduction methods for 2 and 3 dimensional data are proposed and applied to simulated 18F-FDOPA brain images generated from a PET imaging simulator. The methods were applied to investigate whether their utilisation could reduce the bias and error caused by noisy images and improve the accuracy of quantitative measurements. Then, validation step extended to 18F-FDOPA PET images obtained from a clinical trial for Parkinson’s disease. The minimum averaged SE, SSE and the highest averaged reduction of noisy Ki values were found with the feasible generalised least squares (FGLS) model. Battle-Lemarie wavelet (BLW) showed significant change in data for the 3D PET images. Savitzky-Golay filtering (SGF) demonstrated significant change for most of the noise levels applied to 2D data. In clinical 18F-FDOPA images, the mean and standard deviation of standard error (SE) and sum-squared error (SSE) were significantly reduced in both baseline and after therapy groups. This work has the potential to be extended to other graphical analysis in quantitative PET data measurements.

Item Type: Thesis (PhD)
Status: Unpublished
Schools: Engineering
Uncontrolled Keywords: PET Imaging; PET Quantitative Analysis; Patlak Graphical Analysis; 18F-FDOPA Imaging; Irreversible Tracers; Parkinson's Disease PD.
Date of First Compliant Deposit: 30 October 2019
Last Modified: 28 Jul 2020 01:28
URI: https://orca.cardiff.ac.uk/id/eprint/126381

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics