Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Maximal wall thickness measurement in hypertrophic cardiomyopathy

Captur, Gabriella, Manisty, Charlotte H., Raman, Betty, Marchi, Alberto, Wong, Timothy C., Ariga, Rina, Bhuva, Anish, Ormondroyd, Elizabeth, Lobascio, Ilaria, Camaioni, Claudia, Loizos, Savvas, Bonsu-Ofori, Jenade, Turer, Aslan, Zaha, Vlad G., Augutsto, João B., Davies, Rhodri H., Taylor, Andrew J., Nasis, Arthur, Al-Mallah, Mouaz H., Valentin, Sinitsyn, Perez de Arenaza, Diego, Patel, Vimal, Westwood, Mark, Petersen, Steffen E., Li, Chunming, Tang, Lijun, Nakamori, Shiro, Nezafat, Reza, Kwong, Raymond Y., Ho, Carolyn Y., Fraser, Alan G., Watkins, Hugh, Elliott, Perry M., Neubauer, Stefan, Lloyd, Guy, Olivotto, Iacopo, Nihoyannopoulos, Petros and Moon, James C. 2021. Maximal wall thickness measurement in hypertrophic cardiomyopathy. JACC: Cardiovascular Imaging 14 (11) , pp. 2123-2134. 10.1016/j.jcmg.2021.03.032

[thumbnail of Maximum Wall thickness measurement.pdf]
Preview
PDF - Accepted Post-Print Version
Download (14MB) | Preview

Abstract

Objectives The aim of this study was to define the variability of maximal wall thickness (MWT) measurements across modalities and predict its impact on care in patients with hypertrophic cardiomyopathy (HCM). Background Left ventricular MWT measured by echocardiography or cardiovascular magnetic resonance (CMR) contributes to the diagnosis of HCM, stratifies risk, and guides key decisions, including whether to place an implantable cardioverter-defibrillator (ICD). Methods A 20-center global network provided paired echocardiographic and CMR data sets from patients with HCM, from which 17 paired data sets of the highest quality were selected. These were presented as 7 randomly ordered pairs (at 6 cardiac conferences) to experienced readers who report HCM imaging in their daily practice, and their MWT caliper measurements were captured. The impact of measurement variability on ICD insertion decisions was estimated in 769 separately recruited multicenter patients with HCM using the European Society of Cardiology algorithm for 5-year risk for sudden cardiac death. Results MWT analysis was completed by 70 readers (from 6 continents; 91% with >5 years’ experience). Seventy-nine percent and 68% scored echocardiographic and CMR image quality as excellent. For both modalities (echocardiographic and then CMR results), intramodality inter-reader MWT percentage variability was large (range –59% to 117% [SD ±20%] and –61% to 52% [SD ±11%], respectively). Agreement between modalities was low (SE of measurement 4.8 mm; 95% CI 4.3 mm-5.2 mm; r = 0.56 [modest correlation]). In the multicenter HCM cohort, this estimated echocardiographic MWT percentage variability (±20%) applied to the European Society of Cardiology algorithm reclassified risk in 19.5% of patients, which would have led to inappropriate ICD decision making in 1 in 7 patients with HCM (8.7% would have had ICD placement recommended despite potential low risk, and 6.8% would not have had ICD placement recommended despite intermediate or high risk). Conclusions Using the best available images and experienced readers, MWT as a biomarker in HCM has a high degree of inter-reader variability and should be applied with caution as part of decision making for ICD insertion. Better standardization efforts in HCM recommendations by current governing societies are needed to improve clinical decision making in patients with HCM.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Medicine
Publisher: Elsevier
ISSN: 1936-878X
Date of First Compliant Deposit: 23 February 2022
Date of Acceptance: 30 March 2021
Last Modified: 06 Nov 2023 22:29
URI: https://orca.cardiff.ac.uk/id/eprint/147755

Citation Data

Cited 7 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics