Field measurement of natural ventilation rate in an idealised full-scale building located in a staggered urban array: Comparison between tracer gas and pressure-based methods

Gough, H.L., Luo, Z. ORCID: https://orcid.org/0000-0002-2082-3958, Halios, C.H., King, M.-F., Noakes, C.J., Grimmond, C.S.B., Barlow, J.F., Hoxey, R. and Quinn, A.D. 2018. Field measurement of natural ventilation rate in an idealised full-scale building located in a staggered urban array: Comparison between tracer gas and pressure-based methods. Building and Environment 137 , pp. 246-256. 10.1016/j.buildenv.2018.03.055

Full text not available from this repository.

Abstract

Currently, no clear standards exist for determining urban building natural ventilation rates, especially under varying realistic meteorological conditions. In this study, ventilation rates are determined using tracer gas decay and pressure-based measurements for a full-scale (6 m tall) cube. The cube was either isolated (2 months of observations) or sheltered within a staggered array (7 months), for both single-sided and cross ventilation (openings 0.4 m × 1 m). Wind speeds at cube height ranged between 0.04 m s−1 and 13.1 m s−1. Errors for both ventilation methods are carefully assessed. There is no discernible linear relation between normalised ventilation rates from the two methods, except for cross ventilation in the array case. The ratio of tracer gas and pressure derived ventilation rates is assessed with wind direction. For single-sided (leeward opening) cases it approached 1. For cross ventilation the ratio was closer to 1 but with more scatter. One explanation is that agreement is better when internal mixing is less jet-dominated, i.e. for oblique directions in the isolated case and for all directions for unsteady array flows. Sheltering may reduce the flushing rate of the tracer gas from the cube relative to internal mixing rate. This new dataset provides an extensive range of conditions for numerical model evaluation and for understanding uncertainty of ventilation rates. Knowledge of the latter is critical in building design.

Item Type: Article
Date Type: Publication
Schools: Architecture
Publisher: Elsevier
ISSN: 0360-1323
Date of Acceptance: 28 March 2018
Last Modified: 10 Nov 2022 11:43
URI: https://orca.cardiff.ac.uk/id/eprint/151631

Citation Data

Cited 45 times in Scopus. View in Scopus. Powered By Scopus® Data