Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

An evaluation of the effect of blood and human serum on the surface microhardness and surface microstructure of mineral trioxide aggregate

Nekoofar, Mohammad Hossein, Oloomi, K., Sheykhrezae, M. S., Tabor, R., Stone, David F. and Dummer, Paul Michael Howell ORCID: https://orcid.org/0000-0002-0726-7467 2010. An evaluation of the effect of blood and human serum on the surface microhardness and surface microstructure of mineral trioxide aggregate. International Endodontic Journal 43 (10) , pp. 849-858. 10.1111/j.1365-2591.2010.01750.x

Full text not available from this repository.

Abstract

P>Aim Short-term and long-term evaluation of the effect of whole human blood or serum contamination on the surface microhardness value and microstructure of white and grey mineral trioxide aggregate (MTA). Methodology Three groups of 10 samples for each type of MTA were prepared. The first group was mixed with and exposed to fresh whole human blood. The second and third groups were mixed with distilled water and exposed to fresh whole human blood or human serum, respectively. The control group samples were mixed with and exposed to distilled water. During preparation, 1 g of MTA was triturated with 0.33 g of the selected liquid using an amalgamator and placed inside borosilicate cylindrical moulds. The samples were treated with ultrasonic energy. Vickers surface microhardness values were compared after 4 and 180 days. Scanning electron microscopy (SEM) analysis was performed after 4 days. Results White MTA had a greater microhardness value than grey MTA in all groups. There was a significant difference between the control and the experimental groups (P < 0.00001). There was no significant difference between the microhardness values obtained after 4 and 180 days, apart from grey MTA mixed with blood or exposed to serum (P < 0.00001). SEM analysis showed the contaminated samples were devoid of acicular crystals that were prominent in the control groups. Conclusion Blood contamination had a detrimental effect on the surface microhardness of MTA in the short and long term. If blood or serum contamination is unavoidable under clinical conditions, it might be preferable to use white MTA.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Dentistry
Medicine
Uncontrolled Keywords: * blood contamination; * human serum; mineral trioxide aggregate; scanning electron microscopy; trituration; ultrasonic; Vickers surface microhardness;whole human blood
Publisher: Wiley
ISSN: 0143-2885
Last Modified: 18 Oct 2022 13:57
URI: https://orca.cardiff.ac.uk/id/eprint/16003

Citation Data

Cited 58 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item