Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

eBP: a wearable system for frequent and comfortable blood pressure monitoring from user's ear

Bui, Nam, Pham, Nhat, Barnitz, Jessica Jacqueline, Zou, Zhanan, Nguyen, Phuc, Truong, Hoang, Kim, Taeho, Farrow, Nicholas, Nguyen, Anh, Xiao, Jianliang, Deterding, Robin, Dinh, Thang and Vu, Tam 2019. eBP: a wearable system for frequent and comfortable blood pressure monitoring from user's ear. Presented at: MobiCom '19: The 25th Annual International Conference on Mobile Computing and Networking, Los Cabos Mexico, 21-25 October 2019. MobiCom '19: The 25th Annual International Conference on Mobile Computing and Networking. Association for Computing Machinery, pp. 1-17. 10.1145/3300061.3345454

Full text not available from this repository.

Abstract

Frequent blood pressure (BP) assessment is key to the diagnosis and treatment of many severe diseases, such as heart failure, kidney failure, hypertension, and hemodialysis. Current "gold-standard'' BP measurement techniques require the complete blockage of blood flow, which causes discomfort and disruption to normal activity when the assessment is done repetitively and frequently. Unfortunately, patients with hypertension or hemodialysis often have to get their BP measured every 15 minutes for a duration of 4-5 hours or more. The discomfort of wearing a cumbersome and limited mobility device affects their normal activities. In this work, we propose a device called eBP to measure BP from inside the user's ear aiming to minimize the measurement's impact on users' normal activities while maximizing its comfort level. eBP has 3 key components: (1) a light-based pulse sensor attached on an inflatable pipe that goes inside the ear, (2) a digital air pump with a fine controller, and (3) a BP estimation algorithm. In contrast to existing devices, eBP introduces a novel technique that eliminates the need to block the blood flow inside the ear, which alleviates the user's discomfort. We prototyped eBP custom hardware and software and evaluated the system through a comparative study on 35 subjects. The study shows that eBP obtains the average error of 1.8 mmHg and -3.1 mmHg and a standard deviation error of 7.2 mmHg and 7.9 mmHg for systolic (high-pressure value) and diastolic (low-pressure value), respectively. These errors are around the acceptable margins regulated by the FDA's AAMI protocol, which allows mean errors of up to 5 mmHg and a standard deviation of up to 8 mmHg.

Item Type: Conference or Workshop Item (Paper)
Date Type: Published Online
Status: Published
Schools: Computer Science & Informatics
Publisher: Association for Computing Machinery
ISBN: 978-1-4503-6169-9
Date of First Compliant Deposit: 14 August 2023
Date of Acceptance: 11 October 2019
Last Modified: 05 Sep 2023 12:00
URI: https://orca.cardiff.ac.uk/id/eprint/161758

Actions (repository staff only)

Edit Item Edit Item