Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Investigation of Cob construction: Review of mix designs, structural characteristics, and hygrothermal behaviour

Haddad, Kamal, Lannon, Simon ORCID: https://orcid.org/0000-0003-4677-7184 and Latif, Eshrar ORCID: https://orcid.org/0000-0003-3982-6929 2024. Investigation of Cob construction: Review of mix designs, structural characteristics, and hygrothermal behaviour. Journal of Building Engineering 87 , 108959. 10.1016/j.jobe.2024.108959

[thumbnail of 1-s2.0-S2352710224005278-main.pdf] PDF - Published Version
Available under License Creative Commons Attribution.

Download (7MB)

Abstract

Earthen construction systems have potential hygrothermal, and environmental benefits over conventional building materials such as concrete. However, such systems are not yet fully optimised to be part of an energy-efficient building. To further optimise the material, this review explores peer-reviewed research articles that relate to distinct constituents used in cob mixes and the different testing methods used to assess the produced specimen's hygrothermal and structural performance. For data collection, a systematic keyword search was carried out on ScienceDirect, Scopus and Google Scholar search engines, and relevant books were also consulted. The filtering of journal articles was based on studying the abstracts followed by analysing their content within the scope of the review. The results show that the soil's constituents and the added fibre ratios critically affect the percentages of clay and water added to the mixture. Fibres' impact on the mix was experimentally assessed by multiple researchers using distinct types of plant aggregates. The percentage of fibre addition ranged between 0.9% and 3% for structural specimens and reached 25% for non-structural specimens with optimised insulation properties. The investigation of cob's structural performance highlights that the compressive strength of cob has ranged between 0.1 MPa and 2.02 MPa, in contrast, the tensile strengths were between 0.01 MPa and 0.75 MPa. The shear strength was found to range between 0.37 MPa and 0.63 MPa. Furthermore, the hygrothermal exploration of cob demonstrated that the thermal conductivity was ranging between 0.12 W/m.K and 1.06 W/m.K. The review has also reviled that the moisture buffering value (MBV) of different mixtures ranged between 1.06 g m−2 %RH−1 and 1.74 g m−2 %RH−1. The review finds that there is no consensus and robust collated data available about the ratios of the mixes concerning the hygrothermal and structural performance of the specimens. This paper collected the tests results from the literature and highlights the missing results that needs to be considered in further research work.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Architecture
Uncontrolled Keywords: Earthen Construction, Mixing Ratio, Structural Testing, Hygrothermal Testing, Cob
Publisher: Elsevier
ISSN: 2352-7102
Date of First Compliant Deposit: 29 February 2024
Date of Acceptance: 28 February 2024
Last Modified: 12 Mar 2024 10:15
URI: https://orca.cardiff.ac.uk/id/eprint/166658