Machine learning-based frequency spectrum clustering of partial discharge defects in gas-insulated systems filled with technical air and C4-mixture

Ullah, Rahmat, Reid, Alistair ORCID: https://orcid.org/0000-0003-3058-9007, Haddad, Manu ORCID: https://orcid.org/0000-0003-4153-6146, Barnett, Matthew and Taddei, Peter 2026. Machine learning-based frequency spectrum clustering of partial discharge defects in gas-insulated systems filled with technical air and C4-mixture. Presented at: IEEE International Conference on High Voltage Engineering and Application (ICHVE), Sao Paulo, Brazil, 20-25 September 2026. Proceedings of International Conference on High Voltage Engineering and Application. IEEE, 10.1109/ichve72357.2026.11768822

Full text not available from this repository.

Abstract

Driven by the need for sustainable power infrastructure, coupled with increasing regulatory restrictions, the shift toward more environmentally friendly alternatives to SF6 gas has become an area of increasing research focus, but successful deployment of these systems depends upon reliably identifying and classifying their partial-discharge (PD) behaviour. Since gas-insulated switchgear (GIS) plays a vital role in electrical power systems, any failure within it due to PD defects can trigger prolonged outages and significantly affecting large loads or regions. Nevertheless, identifying and distinguishing PD defects remains difficult, especially when multiple sources are active simultaneously in the equipment. This study focuses on identifying different types of partial discharge defects in GIS using criteria derived from PD data and analysed through the K-means clustering method. An ultrahigh frequency (UHF) sensor was used to detect PD signals associated with various insulation issues. The study focuses on two types of environmentally friendly gas insulation gases namely; technical air and C4F7N mixture. Time-domain data were transformed into the frequency domain using fast Fourier transform (FFT) analysis, followed by dimensionality reduction through kernel principal component analysis (KPCA). Finally, the K-means clustering method was applied to the extracted features from the frequency components of various PD sources to define their clusters within the feature space. The results demonstrate that the proposed framework effectively differentiates mixed data corresponding to partial discharge failures in gas-insulated switchgear.

Item Type: Conference or Workshop Item - published (Paper)
Status: Published
Schools: Schools > Engineering
?? AHVER ??
Publisher: IEEE
ISBN: 9798319501363
ISSN: 2381-5043
Last Modified: 23 Nov 2026 14:15
URI: https://orca.cardiff.ac.uk/id/eprint/191124

Actions (repository staff only)

Edit Item Edit Item