Grainger, William F., Ade, Peter A. R., Hargrave, Peter Charles, Chase, S., Kiernan, Brian John and North, Christopher E. 2010. Thermal architecture for the Clover cryostats. Presented at: Modern Technologies in Space- and Ground-Based Telescopes and Instrumentation, San Diego, CA, USA, 27 June-2 July 2010. Published in: Atad-Ettedgui, E. and Lemke, D. eds. Modern Technologies in Space- and Ground-based Telescopes and Instrumentation (Proceedings Volume): 27 June 2010, San Diego, California, USA. Proceedings of SPIE , vol. 7739. Bellingham, WA: SPIE, p. 773916. 10.1117/12.858022 |
Official URL: http://spiedigitallibrary.org/proceedings/resource...
Abstract
We discuss the Clover cryostats, which are dry cryostats containing three stages of cooling; a pulse tube cooler, a sorption fridge and a continuous miniature dilution refrigerator. We describe the thermal architecture of the system and present thermal data for the various stages including its performance when tilted.
Item Type: | Conference or Workshop Item (Paper) |
---|---|
Date Type: | Publication |
Status: | Published |
Schools: | Physics and Astronomy |
Subjects: | Q Science > QB Astronomy |
Publisher: | SPIE |
ISBN: | 9780819482297 |
Last Modified: | 05 Feb 2022 10:44 |
URI: | https://orca.cardiff.ac.uk/id/eprint/22415 |