Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Interlaminar insulation faults detection and quality assessment of magnetic cores using flux injection probe

Hamzehbahmani, Hamed, Anderson, Philip ORCID: https://orcid.org/0000-0001-6500-6583 and Jenkins, Keith 2015. Interlaminar insulation faults detection and quality assessment of magnetic cores using flux injection probe. IEEE Transactions on Power Delivery 30 (5) , pp. 2205-2214. 10.1109/TPWRD.2015.2413900

Full text not available from this repository.

Abstract

Interlaminar faults between laminations of the magnetic cores increase core losses and could cause major damage to electrical machines. A system has been developed to detect an interlaminar fault between the laminations of the magnetic cores by means of the flux injection probe (FIP). Experimental work was carried out to calibrate the measuring system and qualify its accuracy over a wide measurement range. Application of a prototype FIP to quality assessment of transformer laminations was investigated in two stages: 1) inspection of stack of laminations with known interlaminar faults applied by artificial shorts and 2) inspection of stack of laminations with unknown quality. The experimental results show that the developed system is capable of detecting an interlaminar fault between as few as two laminations.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Engineering
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Publisher: Institute of Electrical and Electronics Engineers (IEEE)
ISSN: 0885-8977
Last Modified: 28 Oct 2022 09:21
URI: https://orca.cardiff.ac.uk/id/eprint/74248

Citation Data

Cited 14 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item