Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Comparison of chaotic and sinusoidal vasomotion in the regulation of microvascular flow

Parthimos, Dimitris ORCID: https://orcid.org/0000-0003-3852-323X, Edwards, David Hughes and Griffith, T. M. 1996. Comparison of chaotic and sinusoidal vasomotion in the regulation of microvascular flow. Cardiovascular Research 31 (3) , pp. 388-399. 10.1016/S0008-6363(95)00123-9

Full text not available from this repository.

Abstract

Objective: In order to elucidate the physiological consequences of irregular vasomotion on microvascular flow we have compared the theoretical hydrodynamic consequences of sinusoidal and chaotic fluctuations in the diameter of a single resistance vessel. Methods: In initial experimental studies vasomotion was induced by histamine in isolated rabbit ear resistance arteries (~150 μm diameter) perfused with physiological buffer under both controlled-flow and controlled-pressure conditions. The phase relationships between the observed oscillations in flow and pressure were used to validate a theoretical electrical circuit in which vasomotion was simulated as sinusoidal or as chaotic fluctuations in distal resistance, with compliance incorporated as a parallel capacitance. Results: In both the experimental and theoretical situation, oscillations in flow led those in pressure by ~90 ° in controlled-flow mode, whereas they were ~180 ° out of phase in controlled-pressure mode. In the theoretical model an increase in the amplitude of sinusoidal or chaotic diameter fluctuations enhanced flow, but “paradoxically” increased both time-averaged resistance and conductance. The model showed that with sinusoidal fluctuations the “efficiency” of perfusion (i.e., flow/viscous work expended in perfusing the vessel undergoing vasomotion) exhibited a peak whose magnitude was a function of vasomotion amplitude and the proximal capacitance in the circuit, and was attributable to transient release of charge from this capacitance. This phenomenon was not observed in simulations with chaotic vasomotion. Hydrodynamic effects specific to the presence of chaotic dynamics (e.g., abrupt increases or decreases in flow under the variation of a single parameter) were also evident when the intrinsic complexity of the vasomotion, rather than its amplitude, was varied. Conclusions: The model suggests (i) that vasomotion may serve to increase flow, (ii) that conductance provides a more accurate physiological measure of the functional consequences of active vasomotion than resistance, (iii) that chaotic vasomotion dissipates transients more readily than sinusoidal vasomotion, thereby conferring greater stability to microcirculatory perfusion and (iv) that specific modes of chaotic vasomotion may influence flow independently of their amplitude.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Medicine
Subjects: R Medicine > R Medicine (General)
Uncontrolled Keywords: Chaos; Microvascular flow; Rabbit, artery
Publisher: Elsevier
ISSN: 0008-6363
Last Modified: 28 Oct 2022 08:49
URI: https://orca.cardiff.ac.uk/id/eprint/72316

Citation Data

Cited 66 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item