Tamboli, Vibha
2017.
Detection of prostate cancer biomarker using
molecularly imprinted polymers.
PhD Thesis,
Cardiff University.
Item availability restricted. |
Preview |
PDF
- Accepted Post-Print Version
Download (18MB) | Preview |
PDF
- Supplemental Material
Restricted to Repository staff only Download (287kB) |
Abstract
Successful treatment of prostate cancer (PCa) depends on early diagnosis and screening, which currently relies on the measurement of serum prostate specific antigen (PSA) levels. The overarching aim of the project was to generate molecularly imprinted polymers for PCa biomarkers, with subsequent integration with a sensing platform to allow for rapid, point of care detection and monitoring. The initial work involved the use of simple PSA epitopes for epitope imprinting using conventional imprinting techniques. A four amino acid sequence from the Cterminus of PSA was imprinted with MAA, Aam and Urea monomers to obtain bulk imprinted polymers. Apparent Kd of 102 μM, 154 μM, 194 μM was obtained for MAA, AAm, Urea based bulk mini-MIPs respectively. Epitope imprinting was further developed using a surface imprinting approach, via electropolymersiation of dopamine to detect an epitopic sequence from pro-PSA. An improvement in Kd from bulk-imprinted polymers, with an apparent Kd of 2.9 μM was obtained with the surface electrochemical MIP sensor. However, both epitope imprinting technique lacked sensitivity to measure clinical relevant concentrations of PSA (nM range). As a consequence, a more sophisticated technique called hybrid imprinting was developed to build an electrochemical MIP sensor. Hybrid MIP imprinting utilised an aptamer with established affinity towards PSA to trap the aptamer-PSA complex into a surface grown electropolymer (polydopamine). The resulting aptamer lined polymer pockets exhibited high selectivity and affinity towards PSA (apparent Kd 0.3 nM). The apta-MIP sensor was also able to discriminate from a homologous protein (human Kallikrein 2) and was resilient to fouling from serum proteins. The apta-MIP sensor was further translated to a MOSFET device whereby successful detection of PSA at clinically relevant concentration was obtained in human plasma. Although good sensitivity and selectivity was obtained with the hybrid-MIP sensors, further research is required to understand the binding mechanism of the template to the MIP.
Item Type: | Thesis (PhD) |
---|---|
Date Type: | Completion |
Status: | Unpublished |
Schools: | Pharmacy |
Subjects: | Q Science > Q Science (General) |
Uncontrolled Keywords: | Molecularly Imprinted Polymers, Prostate Cancer, Prostate Specific Antigen, Electrochemical Sensing, Biosensors, Electrochemical MIPs, Epitope Imprinting, Aptamer, Hybrid molecular imprinting, Polydopamine. |
Date of First Compliant Deposit: | 16 August 2017 |
Last Modified: | 19 Oct 2021 01:16 |
URI: | https://orca.cardiff.ac.uk/id/eprint/103518 |
Actions (repository staff only)
Edit Item |