Widger, Phillip ORCID: https://orcid.org/0000-0002-0662-8590 and Haddad, Abderrahmane ORCID: https://orcid.org/0000-0003-4153-6146 2017. Solid by-products of a CF3I-CO2 insulating gas mixtures on electrodes after lightning impulse breakdown. Journal of Physics Communications 1 (2) , 025010. 10.1088/2399-6528/aa8ab4 |
Preview |
PDF
- Published Version
Available under License Creative Commons Attribution. Download (5MB) | Preview |
Abstract
This paper investigates the solid by-products of CF3I–CO2 gas mixtures and their proposed use as an alternative insulation medium in gas insulated switchgear and lines. The deposited by-products of a 30%–70% CF3I–CO2 gas mixture are experimentally investigated using stainless steel, aluminium and copper contacts whilst a standard 50 kV lightning impulse is used to cause electrical breakdown in the gas mixture. Following breakdown, the accumulated by-products over the electrodes surface were examined using an imaging microscope and scanning electron microscope. This paper discusses the results of microscope analysis on the surface of the electrodes and explores the effects that the detected by-products could have on high voltage CF3I–CO2 gas insulated equipment.
Item Type: | Article |
---|---|
Date Type: | Publication |
Status: | Published |
Schools: | Engineering |
Publisher: | IOP Sciences |
ISSN: | 2399-6528 |
Date of First Compliant Deposit: | 29 September 2017 |
Date of Acceptance: | 6 September 2017 |
Last Modified: | 04 May 2023 22:57 |
URI: | https://orca.cardiff.ac.uk/id/eprint/105052 |
Citation Data
Cited 7 times in Scopus. View in Scopus. Powered By Scopus® Data
Actions (repository staff only)
Edit Item |