Haddad, Abderrahmane ORCID: https://orcid.org/0000-0003-4153-6146, Naylor, P., Metwally, I. A., German, D.M. and Waters, Ronald
1995.
An Improved Non-Inductive Impulse Voltage Measurement Technique for ZnO Surge Arresters.
IEEE Transactions on Power Delivery
10
(2)
, pp. 778-785.
10.1109/61.400853
|
Official URL: http://dx.doi.org/10.1109/61.400853
Abstract
One of the most important parameters of the protective performance of ZnO surge arresters is the residual voltage. In laboratory tests on standard arresters, a thin ZnO disc with a central hole is used in order to pick up the voltage, and a system with a double shielding technique reduces outside effects. Comparative tests of voltage signals from this series divider with those from a conventional parallel connected divider show that inductive overshoot is avoided
| Item Type: | Article |
|---|---|
| Status: | Published |
| Schools: | Schools > Engineering |
| Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
| Publisher: | The Institution of Electrical Engineers |
| ISSN: | 08858977 |
| Last Modified: | 03 Nov 2022 10:11 |
| URI: | https://orca.cardiff.ac.uk/id/eprint/107183 |
Citation Data
Cited 9 times in Scopus. View in Scopus. Powered By Scopus® Data