Murray, Julia, Gulliford, Sarah, Griffin, Clare, Wilkins, Anna, Syndikus, Isabel, Staffurth, John ORCID: https://orcid.org/0000-0002-7834-3172, Panades, Miguel, Scrase, Christopher, Parker, Chris, Khoo, Vincent, Dean, Jamie, Mayles, Helen, Mayles, Philip, Thomas, Simon, Naismith, Olivia, Mossop, Helen, Hall, Emma, Dearnaley, David and Cruikshank, Clare 2020. Evaluation of erectile potency and radiation dose to the penile bulb using image guided radiotherapy in the CHHiP trial. European Urology 21 , pp. 77-84. 10.1016/j.ctro.2019.12.006

[thumbnail of 1-s2.0-S2405630819301193-main.pdf]
Preview
PDF - Published Version
Available under License Creative Commons Attribution Non-commercial No Derivatives.

Download (1MB) | Preview

Abstract

Background and purpose The penile bulb (PB) dose may be critical in development of post prostate radiotherapy erectile dysfunction (ED). This study aimed to generate PB dose constraints based on dose-volume histograms (DVHs) in patients treated with prostate radiotherapy, and to identify clinical and dosimetric parameters that predict the risk of ED post prostate radiotherapy. Materials and methods Penile bulb DVHs were generated for 276 patients treated within the randomised IGRT substudy of the multicentre randomised trial, CHHiP. Incidence of ED in relation to dose and randomised IGRT groups were evaluated using Wilcoxon rank sum, Chi-squared test and atlases of complication incidence. Youden index was used to find dose-volume constraints that discriminated for ED. Multivariate analysis (MVA) of effect of dosimetry, clinical and patient-related variables was performed. Results Reduced treatment margins using IGRT (IGRT-R) produced significantly reduced mean PB dose compared with standard margins (IGRT-S) (median: 25 Gy (IGRT-S) versus 11 Gy (IGRT-R); p < 0.0001). Significant difference in both mean (median: 23 Gy (ED) vs. 18 Gy (no ED); p = 0.011) and maximum (median: 59 Gy (ED) vs. 52 Gy (no ED); p = 0.018) PB doses between those with and without clinician reported ED were identified. Mean PB dose cut-point for ED was derived at around 20 Gy. On MVA, PB mean dose and age predicted for impotence. Conclusion PB dose appears predictive of post-radiotherapy ED with calculated threshold mean dose of around 20 Gy, substantially lower than published recommendations. IGRT-R enables favourable PB dosimetry and can be recommended provided prostate coverage is not compromised.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Medicine
Additional Information: Creative Commons Attribution – NonCommercial – NoDerivs (CC BY-NC-ND 4.0)
Publisher: Elsevier
ISSN: 0302-2838
Date of First Compliant Deposit: 12 October 2018
Date of Acceptance: 29 December 2019
Last Modified: 04 May 2023 13:46
URI: https://orca.cardiff.ac.uk/id/eprint/115809

Citation Data

Cited 10 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics