| Aboobaker, Asad M., Ade, Peter  ORCID: https://orcid.org/0000-0002-5127-0401, Araujo, Derek, Aubin, François, Baccigalupi, Carlo, Bao, Chaoyun, Chapman, Daniel, Didier, Joy, Dobbs, Matt, Geach, Christopher, Grainger, Will, Hanany, Shaul, Helson, Kyle, Hillbrand, Seth, Hubmayr, Johannes, Jaffe, Andrew, Johnson, Bradley, Jones, Terry, Klein, Jeff, Korotkov, Andrei, Lee, Adrian, Levinson, Lorne, Limon, Michele, MacDermid, Kevin, Matsumura, Tomotake, Miller, Amber D., Milligan, Michael, Raach, Kate, Reichborn-Kjennerud, Britt, Sagiv, Ilan, Savini, Giorgio, Spencer, Locke, Tucker, Carole  ORCID: https://orcid.org/0000-0002-1851-3918, Tucker, Gregory S.  ORCID: https://orcid.org/0000-0002-1851-3918, Westbrook, Benjamin, Young, Karl and Zilic, Kyle
      2018.
      
      The EBEX balloon-borne experiment-optics, receiver, and polarimetry.
      Astrophysical Journal Supplement
      239
      
        (1)
      
      , p. 7.
      
      10.3847/1538-4365/aae434 | 
| Preview | PDF
 - Published Version Download (5MB) | Preview | 
Abstract
The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic microwave background (CMB) polarimeter that flew over Antarctica in 2012. We describe the experiment's optical system, receiver, and polarimetric approach and report on their in-flight performance. EBEX had three frequency bands centered on 150, 250, and 410 GHz. To make efficient use of limited mass and space, we designed a 115 cm2 sr high-throughput optical system that had two ambient temperature mirrors and four antireflection-coated polyethylene lenses per focal plane. All frequency bands shared the same optical train. Polarimetry was achieved with a continuously rotating achromatic half-wave plate (AHWP) that was levitated with a superconducting magnetic bearing (SMB). This is the first use of an SMB in astrophysics. Rotation stability was 0.45% over a period of 10 hr, and angular position accuracy was 0fdg01. The measured modulation efficiency was above 90% for all bands. To our knowledge the 109% fractional bandwidth of the AHWP was the broadest implemented to date. The receiver, composed of one lens and the AHWP at a temperature of 4 K, the polarizing grid and other lenses at 1 K, and the two focal planes at 0.25 K, performed according to specifications, giving focal plane temperature stability with a fluctuation power spectrum that had a 1/f knee at 2 mHz. EBEX was the first balloon-borne instrument to implement technologies characteristic of modern CMB polarimeters, including high-throughput optical systems, and large arrays of transition edge sensor bolometric detectors with multiplexed readouts.
| Item Type: | Article | 
|---|---|
| Date Type: | Publication | 
| Status: | Published | 
| Schools: | Schools > Physics and Astronomy | 
| Publisher: | American Astronomical Society | 
| ISSN: | 0067-0049 | 
| Date of First Compliant Deposit: | 20 December 2018 | 
| Date of Acceptance: | 22 November 2017 | 
| Last Modified: | 24 Oct 2025 21:27 | 
| URI: | https://orca.cardiff.ac.uk/id/eprint/117847 | 
Citation Data
Cited 18 times in Scopus. View in Scopus. Powered By Scopus® Data