Tsang, Yatman, Hoskin, Peter, Spezi, Emiliano ORCID: https://orcid.org/0000-0002-1452-8813, Landau, David, Lester, Jason, Miles, Elizabeth and Conibear, John 2019. Assessment of contour variability in target volumes and organs at risk in lung cancer radiotherapy. Technical Innovations and Patient Support in Radiation Oncology 10 , pp. 8-12. 10.1016/j.tipsro.2019.05.001 |
Preview |
PDF
- Published Version
Available under License Creative Commons Attribution Non-commercial No Derivatives. Download (951kB) | Preview |
Abstract
Aims This study aimed to examine whether any significant differences existed in trial protocol compliance in target volumes (TV) and organs at risk (OARs) contouring amongst clinical oncologists specialised in lung cancer radiotherapy. Materials/methods Two lung radiotherapy trials that require all prospective investigators to submit pre-trial outlining quality assurance (QA) benchmark cases were selected. The contours from the benchmark cases were compared against a set of reference contours which were defined by the trial management group (TMG). In order to quantify the degree of variation in TV and OARs contouring, the matching index (MI), Dice coefficient (DICE), Jaccard index (JI), Van‘t Riet Index and geographical miss index (GMI) were calculated. Results A total of 198 structures contoured by 21 clinicians were collected from the outlining benchmark cases. There were 40 clinical target volumes (CTV), 32 spinal cord, 36 oesophagus, 36 heart and 54 lungs volumes included in the study. Analysis of the pre-trial benchmark cases revealed statistically significant differences (p ≤ 0.05) in trial protocol compliances between clinical oncologists’ target volume and organs at risk contours. Our results demonstrated that the lung contours had the highest level of conformity, followed by heart, CTV, spinal cord and oesophagus respectively. Conclusions This study showed that there was a statistically significant difference in trial protocol compliance for lung clinical oncologists’ TV and OARs contouring within the pre-trial QA benchmark cases. Trial protocol compliances of TV and OARs delineation can be identified through assessing outlining QA benchmark cases.
Item Type: | Article |
---|---|
Date Type: | Publication |
Status: | Published |
Schools: | Engineering |
Publisher: | Elsevier |
ISSN: | 2405-6324 |
Date of First Compliant Deposit: | 26 June 2019 |
Date of Acceptance: | 21 May 2019 |
Last Modified: | 05 May 2023 15:44 |
URI: | https://orca.cardiff.ac.uk/id/eprint/123754 |
Citation Data
Cited 13 times in Scopus. View in Scopus. Powered By Scopus® Data
Actions (repository staff only)
Edit Item |