Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Ageing changes in retinal outer nuclear layer thickness and cone photoreceptor density using adaptive optics-free imaging

Matlach, Juliane, Mulholland, Padraig J., Cilkova, Marketa, Chopra, Reena, Shah, Nilpa, Redmond, Tony ORCID: https://orcid.org/0000-0002-6997-5231, Dakin, Steven C., Garway-Heath, David F. and Anderson, Roger S. 2023. Ageing changes in retinal outer nuclear layer thickness and cone photoreceptor density using adaptive optics-free imaging. European Journal of Ophthalmology 33 (3) , pp. 1434-1442. 10.1177/11206721221144477

[thumbnail of Matlach et al 2022_InPress.pdf]
Preview
PDF - Accepted Post-Print Version
Download (794kB) | Preview

Abstract

Purpose To investigate age-related changes of the outer nuclear layer (ONL) thickness and cone density, and their associations in healthy participants using a modified, narrow scan-angle Heidelberg Retina Angiograph (HRA2). Methods Retinal cones were imaged outside the fovea at 8.8° eccentricity and cone density was compared to ONL thickness measurements obtained by Spectral-Domain Optical Coherence Tomography (SD-OCT) at the same locations. Fifty-six eyes of 56 healthy participants with a median age (interquartile range, IQR) of 37 years (29–55) were included. Results Median (IQR) cone count was 7,472 (7,188, 7,746) cones/mm2 and median (IQR) ONL thickness was 56 (52, 60) µm for healthy participants. Both cone density and ONL thickness were negatively associated with age: cone density, R2 = 0.16 (F(1,54) = 10.41, P = 0.002); ONL thickness, R2 = 0.12 (F(1,54) = 7.41, P = 0.009). No significant association was seen between cone density and ONL thickness (R2 = 0.03; F(1,54) = 1.66, P = 0.20). Conclusion Cone density was lower, and ONL thinner, in older compared to younger participants, therefore, image-based structural measures should be compared to age-related data. However, cone density and ONL thickness were not strongly associated, indicating that determinants of ONL thickness measurements other than cone density measurements, and including measurement error, have a major influence.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Optometry and Vision Sciences
Publisher: Wichtig Editore
ISSN: 1724-6016
Funders: Fight For Sight, Dr. Werner Jackstädt-Stiftung Foundation
Date of First Compliant Deposit: 1 December 2022
Date of Acceptance: 23 November 2022
Last Modified: 28 Feb 2024 07:39
URI: https://orca.cardiff.ac.uk/id/eprint/154593

Citation Data

Cited 1 time in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics