Kumar, Manish ORCID: https://orcid.org/0000-0002-0616-3746 and Jayaraman, Kalaiselvi
2020.
Common mode impedance shaping choke to attenuate the conducted EMI in three phase drive.
Presented at: 2020 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES),
Jaipur, India,
16-19 December 2020.
2020 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES).
IEEE,
10.1109/PEDES49360.2020.9379346
|
Abstract
This paper presents an impedance shaping technique to reshape the common mode (CM) impedance profile of three phase common mode choke. The CM impedance offered by a designed CM choke with specific core area and number of turns is reshaped using CMIS choke. CM noise in a two level voltage source inverter (TL-VSI) has dominant frequency components near inverter switching frequency ( Fsw ). Attenuation of these dominant frequency components demand high impedance at Fsw . A designed CMIS choke offers high CM impedance for Fsw compared to CCM choke. The proposed three phase CMIS choke is a passive CM noise attenuation technique that attenuates the dominant Fsw components. The CM attenuation performance of passive EMI filter with CMIS choke and CCM choke are compared for TL-VSI.