Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Inter-slice leakage and intra-slice aliasing in simultaneous multi-slice echo-planar images

McNabb, Carolyn Beth ORCID: https://orcid.org/0000-0002-6434-5177, Lindner, Michael, Shen, Shan, Burgess, Laura Grace, Murayama, Kou and Johnstone, Tom 2020. Inter-slice leakage and intra-slice aliasing in simultaneous multi-slice echo-planar images. Brain Structure and Function 225 (3) , pp. 1153-1158. 10.1007/s00429-020-02053-2

[thumbnail of s00429-020-02053-2.pdf]
Preview
PDF - Published Version
Available under License Creative Commons Attribution.

Download (1MB) | Preview

Abstract

Simultaneous multi-slice (SMS) imaging is a popular technique for increasing acquisition speed in echo-planar imaging (EPI) fMRI. However, SMS data are prone to motion sensitivity and slice leakage artefacts, which spread signal between simultaneously acquired slices. Relevant to motion sensitivity, artefacts from moving anatomic structures propagate along the phase-encoding (PE) direction. This is particularly relevant for eye movement. As signal from the eye is acquired along with signal from simultaneously excited slices during SMS, there is potential for signal to spread in-plane and between spatially remote slices. After identifying an artefact temporally coinciding with signal fluctuations in the eye and spatially distributed in correspondence with multiband slice acceleration and parallel imaging factors, we conducted a series of small experiments to investigate eye movement artefacts in SMS data and the contribution of PE direction to the invasiveness of these artefacts. Five healthy adult volunteers were scanned during a blinking task using a standard SMS-EPI protocol with posterior-to-anterior (P ≫ A), anterior-to-posterior (A ≫ P) or right-to-left (R ≫ L) PE direction. The intensity of signal fluctuations (artefact severity) was measured at expected artefact positions and control positions. We demonstrated a direct relationship between eye movements and artefact severity across expected artefact regions. Within-brain artefacts were apparent in P ≫ A- and A ≫ P-acquired data but not in R ≫ L data due to the shift in artefact positions. Further research into eye motion artefacts in SMS data is warranted but researchers should exercise caution with SMS protocols. We recommend rigorous piloting of SMS protocols and switching to R ≫ L/L ≫ R PE where feasible.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Psychology
Publisher: Springer
ISSN: 1863-2653
Date of First Compliant Deposit: 13 November 2023
Date of Acceptance: 21 February 2020
Last Modified: 02 Jul 2024 01:33
URI: https://orca.cardiff.ac.uk/id/eprint/162760

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics