Shah, R., Finlay, A.Y. ORCID: https://orcid.org/0000-0003-2143-1646, Salek, M.S., Allen, H., Nixon, S.J., Nixon, M., Otwombe, K., Ali, F.M. and Ingram, J.R. ORCID: https://orcid.org/0000-0002-5257-1142 2024. Responsiveness and minimal important change of the Family Reported Outcome Measure (FROM-16). Journal of Patient-Reported Outcomes 8 (1) , 38. 10.1186/s41687-024-00703-1 |
PDF
- Supplemental Material
Available under License Creative Commons Attribution. Download (931kB) |
|
PDF
- Published Version
Available under License Creative Commons Attribution. Download (822kB) |
Abstract
Background: The FROM-16 is a generic family quality of life (QoL) instrument that measures the QoL impact of patients’ disease on their family members/partners. The study aimed to assess the responsiveness of FROM-16 to change and determine Minimal Important Change (MIC). Methods: Responsiveness and MIC for FROM-16 were assessed prospectively with patients and their family members recruited from outpatient departments of the University Hospital Wales and University Hospital Llandough, Cardiff, United Kingdom. Patients completed the EQ-5D-3L and a global severity question (GSQ) online at baseline and at 3-month follow-up. Family members completed FROM-16 at baseline and a Global Rating of Change (GRC) in addition to FROM-16 at follow-up. Responsiveness was assessed using the distribution-based (effect size-ES, standardized response mean -SRM) and anchor-based (area under the receiver operating characteristics curve ROC-AUC) approaches and by testing hypotheses on expected correlation strength between FROM-16 change score and patient assessment tools (GSQ and EQ-5D). Cohen’s criteria were used for assessing ES. The AUC ≥ 0.7 was considered a good measure of responsiveness. MIC was calculated using anchor-based (ROC analysis and adjusted predictive modelling) and distribution methods based on standard deviation (SD) and standard error of the measurement (SEM). Results: Eighty-three patients with 15 different health conditions and their relatives completed baseline and follow-up questionnaires and were included in the responsiveness analysis. The mean FROM-16 change over 3 months = 1.43 (SD = 4.98). The mean patient EQ-5D change over 3 months = −0.059 (SD = 0.14). The responsiveness analysis showed that the FROM-16 was responsive to change (ES = 0.2, SRM = 0.3; p < 0.01). The ES and SRM of FROM-16 change score ranged from small (ES = 0.2; SRM = 0.3) for the distribution-based method to large (ES = 0.8, SRM = 0.85) for anchor-based methods. The AUC value was above 0.7, indicating good responsiveness. There was a significant positive correlation between the FROM-16 change scores and the patient’s disease severity change scores (p < 0.001). The MIC analysis was based on data from 100 family members of 100 patients. The MIC value of 4 was suggested for FROM-16. Conclusions: The results of this study confirm the longitudinal validity of FROM-16 which refers to the degree to which an instrument is able to measure change in the construct to be measured. The results yield a MIC value of 4 for FROM-16. These psychometric attributes of the FROM-16 instrument are useful in both clinical research as well as clinical practice.
Item Type: | Article |
---|---|
Date Type: | Publication |
Status: | Published |
Schools: | Medicine |
Additional Information: | License information from Publisher: LICENSE 1: URL: http://creativecommons.org/licenses/by/4.0/, Type: open-access |
Publisher: | SpringerOpen |
ISSN: | 2509-8020 |
Date of First Compliant Deposit: | 27 March 2024 |
Date of Acceptance: | 15 February 2024 |
Last Modified: | 27 Mar 2024 10:15 |
URI: | https://orca.cardiff.ac.uk/id/eprint/167572 |
Actions (repository staff only)
Edit Item |