Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

An observational study to evaluate the within-day reliability and concurrent validity of 2-minute walk test (2MWT) and 10-meter walk test (10MWT) in healthy individuals while wearing a surgical mask.

Wang, Lu, Wan, Lei, Gale, Nichola S. ORCID: https://orcid.org/0000-0001-5207-9863 and Qin, Yue 2024. An observational study to evaluate the within-day reliability and concurrent validity of 2-minute walk test (2MWT) and 10-meter walk test (10MWT) in healthy individuals while wearing a surgical mask. ACPRC Journal 56 (2) , pp. 21-28. 10.56792/SFKK8730

[thumbnail of acprcjournal_116762(1).pdf]
Preview
PDF - Published Version
Available under License Creative Commons Attribution.

Download (427kB) | Preview

Abstract

Background Exercise tests are widely used to prescribe exercises for patients with cardiorespiratory conditions and assess impact of treatments. The 2-minute walk test (2MWT) and 10-metre walk test (10MWT) are common assessments of functional exercise capacity. The COVID-19 pandemic resulted in people wearing masks (commonly surgical masks) to reduce infection. However, the validity and reliability of 2MWT and 10MWT wearing a mask is unknown and further research is required. Aim To assess the within-day reliability and concurrent validity of the 2MWT and 10MWT in healthy individuals wearing a surgical mask. Design and Setting Observational study, in a university setting Methods All participants completed three tests of 2MWT and 10MWT wearing a surgical mask (on one day) and one test without a mask (on a separate day) within one week. Oxygen saturation and heart rate were measured using pulse oximetry and the Borg scale assessed dyspnoea. Statistical analyses included: intraclass correlation coefficients (ICC) for within-day reliability of mask-wearing during three tests and Pearson’s coefficient for concurrent validity correlated tests with a surgical mask and without a mask (the gold standard). Results 15 people, mean (standard deviation) age 26 (2) years were included. The 2MWT and 10MWT (with mask) had excellent within-day reliability (ICC =0.823, 0.920 respectively). Both the 2MWT and 10MWT with and without a mask were highly correlated (r = 0.815, 0.943 respectively, p<0.01). Conclusions The results showed excellent within-day reliability and concurrent validity of 2MWT and 10MWT with a surgical mask in healthy individuals. Further research in clinical populations is needed.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Healthcare Sciences
Publisher: Association of Chartered Physiotherapists in Respiratory Care
ISSN: 2059-0199
Date of First Compliant Deposit: 19 April 2024
Date of Acceptance: 19 April 2024
Last Modified: 10 Jun 2024 13:01
URI: https://orca.cardiff.ac.uk/id/eprint/168176

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics