Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Enhancing fault ride-through capacity of DFIG-Based WPs by adaptive backstepping command using parametric estimation in non-linear forward power controller design

Loulijat, Azeddine, Makhad, Mohamed, Hilali, Abdelilah, Chojaa, Hamid, El Marghichi, Mouncef, Hatatah, Mohammed and Alghamdi, Thamer A. H. 2024. Enhancing fault ride-through capacity of DFIG-Based WPs by adaptive backstepping command using parametric estimation in non-linear forward power controller design. IEEE Access 12 , pp. 58675-58689. 10.1109/ACCESS.2024.3381613

[thumbnail of Enhancing_Fault_Ride-Through_Capacity_of_DFIG-Based_WPs_by_Adaptive_Backstepping_Command_Using_Parametric_Estimation_in_Non-Linear_Forward_Power_Controller_Design.pdf] PDF - Published Version
Available under License Creative Commons Attribution Non-commercial No Derivatives.

Download (2MB)

Abstract

The principal issue associated with wind parks (WPs) based on doubly-fed induction generators (DFIGs) is their vulnerability to network faults. This paper presents a novel nonlinear forward power controller design with an adaptive backstepping command using parametric estimation (NFPC_ABC-PE) to enhance fault ride-through (FRT) capacities in WP utilizing DFIGs. The suggested NFPC_ABC-PE manupiles both rotor and network-side power converters (i.e., RSPCs and NSPCs). Specifically, RSPCs are manipulated to maintain the targeted voltage at dc-bus terminals, while NSPCs are manipulated to supply the reactive energy (power) necessary if the network is disturbed. As a result, the NFPC_ABC-PE proposed precisely supplies reactive energy to ensure the smooth execution of FRT ability. The method developed comprehends the dynamics of RSPC, NSPC-side filters, and dc-bus terminal voltage in the form of electrical active and reactive output power. The parameters of the RSPC and NSPC-side filters, including those associated with the dc-bus capacitor, are regarded as entirely unknown. To estimate and regulate these parameters, adaptation algorithms are utilized. The NFPC_ABC-PE employs parameter adaptation algorithms and switching control inputs designed to safeguard the overall stability of WP. The stability analysis of the DFIG-based WPs with the proposed NFPC_ABC-PE involves applying stability in the sense of the Lyapunov function (LF). To validate its efficacy, simulations are carried out on a single 10 MW power generation unit. The results of the simulation highlight a clear enhancement in the stability and FRT capability of WP, contrasting with the nonlinear forward power controller employing the sliding mode command (NFPC-SMC).

Item Type: Article
Date Type: Publication
Status: Published
Schools: Engineering
Publisher: Institute of Electrical and Electronics Engineers
ISSN: 2169-3536
Date of First Compliant Deposit: 5 June 2024
Date of Acceptance: 11 March 2024
Last Modified: 05 Jun 2024 10:00
URI: https://orca.cardiff.ac.uk/id/eprint/169313

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics