Abstract

Tissue slices can undergo distortions during processing into resin for light and electron microscopy as a result of differential shrinkage of the various tissue components, and this may necessitate removal of a considerable amount of material from the final resin‐embedded tissue block to ensure production of complete sections of the sample. To mitigate this problem, a number of techniques have been devised that ensure the sample is held flat during the final curing/polymerisation of the resin. For embedding in acrylic resins, oxygen must be excluded as it inhibits polymerisation, and methods devised for epoxy resin embedding are generally unsuitable. The method describes the preparation and use of air‐tight flat‐embedding chambers prepared from Melinex film and provides an inexpensive, technically simpler, and versatile alternative to chambers formed from either Thermanox coverslips or Aclar films that have previously been advocated for such purposes. Lay description: Tissue slices can undergo distortions during processing into resin for light and electron microscopy as a result of differential shrinkage of the various tissue components. Such distortions may necessitate removal of a considerable amount of material to ensure production of complete sections of the sample. For embedding in acrylic resins, oxygen must be excluded as it inhibits polymerisation, and methods devised for epoxy resin flat‐embedding are generally unsuitable. Air‐tight flat‐embedding chambers prepared from either Thermanox coverslips, or a combination of PTFE‐coated glass slides, polycarbonate film gaskets, and Aclar film have been advocated for such purposes. Thermanox coverslips are expensive and limited in size to 22 mm × 60 mm, and the alternative method is technically complicated. Melinex film is commercially available as 210 mm × 297 mm sheets and is approximately 1/20th the price of Thermanox and less than half the price of Aclar film. The method describes the preparation and use of embedding chambers made from Melinex film, glass slides and double‐sided adhesive tape as a technically simpler, inexpensive and versatile alternative to both Thermanox coverslips and the Aclar film method.

Item Type: Article
Date Type: Published Online
Status: Published
Schools: Medicine
Additional Information: License information from Publisher: LICENSE 1: URL: http://creativecommons.org/licenses/by/4.0/
Publisher: Wiley
ISSN: 0022-2720
Date of First Compliant Deposit: 17 September 2024
Date of Acceptance: 2 September 2024
Last Modified: 11 Oct 2024 15:01
URI: https://orca.cardiff.ac.uk/id/eprint/172157

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics