Schulze, Marc-Matthias, Fadel, Daddi, Luensmann, Doerte, Ng, Alison ORCID: https://orcid.org/0000-0002-6277-8470, Guthrie, Sarah, Woods, Jill and Jones, Lyndon
2023.
Evaluating the performance of verofilcon a daily disposable contact lenses in a group of heavy digital device users.
Clinical Ophthalmology
17
, pp. 3165-3175.
10.2147/OPTH.S429250
|
Abstract
Purpose: The purpose of this study was to evaluate the performance of verofilcon A daily disposable contact lenses (CL) in CL wearers who identified themselves as heavy digital device users. Patients and Methods: This prospective, non-masked, open-label study enrolled CL wearers who reported ≥ 6 hours digital device use per day. Participants were dispensed with the verofilcon A study lenses for 14± 2 days, to be worn for at least 5 days a week and 10 hours per day, while continuing their normal routine of digital device use. Participants rated the lens performance at the Day 14 visit using a 0– 100 (with 100 being best) scale. Ratings were completed at lens insertion, after 6 hours of digital device use, just before CL removal and for overall experience. Participants also completed a 4-point (strongly agree/disagree, slightly agree/disagree) Likert scale-based questionnaire. Results: Thirty-two participants were eligible and completed the study (27 females; age 25.8 ± 6.0 years, ranging from 19 to 40). Overall lens performance ratings at the Day 14 visit (mean ± standard deviation) for comfort, dryness, and clarity of vision were 91 ± 11, 88 ± 11, and 92 ± 9, respectively. Subjective ratings were stable throughout the day with no significant differences after insertion, after 6 hours of digital device use and before CL removal (all p> 0.05). The majority of participants agreed that the study lenses performed well, provided good all-day comfort (28/32; p< 0.01) and good all-day vision (29/32; p< 0.01). Participants also agreed that after ≥ 6 hours of digital device use they were satisfied with CL comfort (27/32; p< 0.01), vision (29/32; p< 0.01) and that the lenses provided good performance (26/32; p< 0.01). Conclusion: Verofilcon A lenses were found to perform well, with high ratings for comfort, dryness and vision that remained high throughout the day, during extensive digital device use.
| Item Type: | Article |
|---|---|
| Date Type: | Publication |
| Status: | Published |
| Schools: | Schools > Optometry and Vision Sciences |
| Publisher: | Dove Medical Press |
| ISSN: | 1177-5467 |
| Date of Acceptance: | 16 October 2023 |
| Last Modified: | 10 Jan 2025 12:15 |
| URI: | https://orca.cardiff.ac.uk/id/eprint/174823 |
Citation Data
Cited 3 times in Scopus. View in Scopus. Powered By Scopus® Data
Actions (repository staff only)
![]() |
Edit Item |





Dimensions
Dimensions