Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Evaluating the performance of verofilcon a daily disposable contact lenses in a group of heavy digital device users

Schulze, Marc-Matthias, Fadel, Daddi, Luensmann, Doerte, Ng, Alison ORCID: https://orcid.org/0000-0002-6277-8470, Guthrie, Sarah, Woods, Jill and Jones, Lyndon 2023. Evaluating the performance of verofilcon a daily disposable contact lenses in a group of heavy digital device users. Clinical Ophthalmology 17 , pp. 3165-3175. 10.2147/OPTH.S429250

Full text not available from this repository.

Abstract

Purpose: The purpose of this study was to evaluate the performance of verofilcon A daily disposable contact lenses (CL) in CL wearers who identified themselves as heavy digital device users. Patients and Methods: This prospective, non-masked, open-label study enrolled CL wearers who reported ≥ 6 hours digital device use per day. Participants were dispensed with the verofilcon A study lenses for 14± 2 days, to be worn for at least 5 days a week and 10 hours per day, while continuing their normal routine of digital device use. Participants rated the lens performance at the Day 14 visit using a 0– 100 (with 100 being best) scale. Ratings were completed at lens insertion, after 6 hours of digital device use, just before CL removal and for overall experience. Participants also completed a 4-point (strongly agree/disagree, slightly agree/disagree) Likert scale-based questionnaire. Results: Thirty-two participants were eligible and completed the study (27 females; age 25.8 ± 6.0 years, ranging from 19 to 40). Overall lens performance ratings at the Day 14 visit (mean ± standard deviation) for comfort, dryness, and clarity of vision were 91 ± 11, 88 ± 11, and 92 ± 9, respectively. Subjective ratings were stable throughout the day with no significant differences after insertion, after 6 hours of digital device use and before CL removal (all p> 0.05). The majority of participants agreed that the study lenses performed well, provided good all-day comfort (28/32; p< 0.01) and good all-day vision (29/32; p< 0.01). Participants also agreed that after ≥ 6 hours of digital device use they were satisfied with CL comfort (27/32; p< 0.01), vision (29/32; p< 0.01) and that the lenses provided good performance (26/32; p< 0.01). Conclusion: Verofilcon A lenses were found to perform well, with high ratings for comfort, dryness and vision that remained high throughout the day, during extensive digital device use.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Optometry and Vision Sciences
Publisher: Dove Medical Press
ISSN: 1177-5467
Date of Acceptance: 16 October 2023
Last Modified: 10 Jan 2025 12:15
URI: https://orca.cardiff.ac.uk/id/eprint/174823

Actions (repository staff only)

Edit Item Edit Item