Simulation study on X-ray radiographic testing of welds

Mousa, Tariq, Taha, Eslam, Alnadwi, Fuad, Siddig, Mohammed and Banoqitah, Essam 2024. Simulation study on X-ray radiographic testing of welds. Presented at: SCOPE: Saudi International Conference On Nuclear Power Engineering, Dhahran, KSA, 13-15 November 2023. Published in: Shams, A., Al-Athel, K., Tiselj, I., Pautz, A. and Kwiatkowski, T. eds. Challenges and Recent Advancements in Nuclear Energy Systems. pp. 58-64. 10.1007/978-3-031-64362-0_7

Full text not available from this repository.

Abstract

Despite the acknowledged advantages that computer simulations can offer to Radiographic Testing, simulation solutions are uncommon in the industry. This paper presents an effective strategy for the simulation of Radiographic Testing techniques using Geant4 Application for Tomographic Emission (GATE), which is a medical imaging software toolkit. Models for X-ray emission, test specimen geometry, radiation interaction with the test specimen, and image receptors were created in GATE. Single Wall Single Image and Double Wall Single Image techniques were set up to evaluate the simulation models. The results showed that GATE can afford a reliable and cost-effective solution in the simulation of radiographic Non-Destructive Testing procedures.