Morris, Rhys J. ORCID: https://orcid.org/0000-0002-9210-1567, Giddings, John Charles, Ralis, Heather M., Jennings, Gwyneth Mai, Davies, Delyth A., Woodcock, John Patrick and Dunstan, Frank David John ORCID: https://orcid.org/0000-0002-1043-5281 2006. The influence of inflation rate on the hematologic and hemodynamic effects of intermittent pneumatic calf compression for deep vein thrombosis prophylaxis. Journal of Vascular Surgery 44 (5) , pp. 1039-1045. 10.1016/j.jvs.2006.06.016 |
Abstract
Objective The study was conducted to determine whether the different inflation rates of intermittent pneumatic compression systems used in deep vein thrombosis prophylaxis influence their hematologic and hemodynamic effects. Methods A rapidly inflating intermittent calf compression system and a more gently inflating equivalent were applied to 20 healthy male volunteers for 2 hours each. Venous blood samples were taken for analysis of blood coagulation and fibrinolytic potential. Blood flow velocity was measured in the femoral vein with Doppler ultrasound. Results Tissue factor pathway inhibitor significantly increased after the 2 hours of compression for both pumps (78.0 to 85.0 ng/mL rapid, P = .004; 76.5 to 78.0 ng/mL gentle, P = .5), as did plasminogen activator activity (0.85 to 1.05 IU/mL rapid, P = .006; 0.85 to 1.5 IU/mL gentle, P = 0.5). Plasminogen activator inhibitor 1 activity was reduced, although only approaching significance for the gentle system (16.5 to 14.3 AU/mL, P = .06). A D-dimer test for global fibrinolysis showed significant increases for the gently inflating system (97 to 411 ng/mL P < .001) but not for the rapidly inflating system (276 to 350 ng/mL P = .9). The rapidly inflating system produced significantly higher venous peak velocities and augmentations as expected. Conclusions Although the data confirm that both types of intermittent compression suppress procoagulant activation, rapid inflation clearly produced no extra benefit in increasing global fibrinolysis, and may be less hematologically effective.
Item Type: | Article |
---|---|
Date Type: | Publication |
Status: | Published |
Schools: | Engineering Medicine Neuroscience and Mental Health Research Institute (NMHRI) |
Subjects: | Q Science > QC Physics R Medicine > R Medicine (General) T Technology > TJ Mechanical engineering and machinery |
ISSN: | 0741-5214 |
Last Modified: | 26 Apr 2023 01:05 |
URI: | https://orca.cardiff.ac.uk/id/eprint/2131 |
Citation Data
Cited 17 times in Scopus. View in Scopus. Powered By Scopus® Data
Actions (repository staff only)
Edit Item |