Hayes, J. S., Seidenglanz, U., Pearce, A. I., Pearce, S. G., Archer, Charles William and Richards, R. G. 2010. Surface polishing positively influences ease of plate and screw removal. European Cells and Materials 19 , pp. 117-126. |
Abstract
Difficulties removing temporary fracture fixation devices due to excessive bony on-growth results in extended surgical time leading to excessive blood loss, debris contamination and potentially refracture. Commercially available locking plates and screws are manufactured for clinics with a micro-rough surface, which contributes to the excessive bony on-growth reported. We have applied polishing technology to commercially pure titanium locking compression plates (LCP) and titanium-6%aluminium-7%niobium (TAN) plates and screws to assess if it can alleviate problems with strong bony overgrowth. Samples were implanted for 6, 12 and 18 months in a bilateral sheep tibia non fracture model and assessed for screw removal torque, percentage of bone contact and tissue-material response. Both electropolishing (p=0.001) and paste polishing (p=0.010) of TAN screws significantly reduced the mean torque required for removal compared to their micro-rough counterparts. This was accompanied by a trend for a lower percentage of bone contact for polished screws. This difference in bone contact was significant for paste polished TAN screws (p<0.001) but not electropolished TAN screws (p=0.066). Ex vivo, soft tissue removal was much easier (~five minutes) for polished constructs, which was difficult and at least four times longer for standard micro-rough constructs. We suggest that polishing of locked plate/screw systems will improve ease of removal and reduce implant related removal complications encountered due to excessive strong bony on-growth while maintaining biocompatibility and implant stability. Future studies aim to assess the potential of this technology in the next level of complication, a fracture model.
Item Type: | Article |
---|---|
Date Type: | Publication |
Status: | Published |
Schools: | Biosciences |
Subjects: | Q Science > Q Science (General) |
Uncontrolled Keywords: | implant removal; in vivo; locking compression plate; screw removal; commercially pure titanium; titanium-6%aluminium-7%niobium |
Publisher: | AO Foundation |
ISSN: | 1473-2262 |
Last Modified: | 19 Mar 2016 22:48 |
URI: | https://orca.cardiff.ac.uk/id/eprint/27916 |
Citation Data
Cited 35 times in Scopus. View in Scopus. Powered By Scopus® Data
Actions (repository staff only)
![]() |
Edit Item |