Benedikt, Johannes ORCID: https://orcid.org/0000-0002-9583-2349, Gaddi, R., Tasker, Paul J. ORCID: https://orcid.org/0000-0002-6760-7830, Goss, M. and Zadeh, M. 2000. High power time domain measurement system with active harmonic load-pull for high efficiency base station amplifier design. Presented at: 2000 IEEE MTT-S International Microwave Symposium, Boston, MA, USA, 11-16 June 2000. Published in: Perkins, T. ed. 2000 IEEE MTT-S International Microwave Symposium Digest. , vol.3 Los Alamitos, CA: IEEE, pp. 1459-1462. 10.1109/MWSYM.2000.862249 |
Official URL: http://dx.doi.org/10.1109/MWSYM.2000.862249
Abstract
A measurement system combining vector corrected waveform measurements with active harmonic load-pull extends, for the first time, real-time experimental waveform engineering up to the 30 W power level. This novel harmonic load-pull approach is demonstrated on a 4 W LDMOS device. A 20% increase in maximum output power to 4.7 W without degrading gain and efficiency was realized.