Sheraton, T. E., Gildersleve, C. and Hall, Judith Elizabeth ORCID: https://orcid.org/0000-0002-6770-7372 2007. The use of nitrous oxide in paediatric anaesthetic practice in the United Kingdom: a questionnaire survey. Anaesthesia -London- 62 (1) , pp. 62-66. 10.1111/j.1365-2044.2006.04857.x |
Abstract
Nitrous oxide pollution is common in paediatric anaesthetic practice. A questionnaire was sent to all UK members of the Association of Paediatric Anaesthetists requesting details of three areas of their paediatric practice relating to nitrous oxide: attitudes to its use; current usage; and availability of alternatives. Replies were received from 296 (68%) consultants. Of these, 169 (57%) stated that their use of nitrous oxide had decreased over the last 5 years. One hundred and fifty-eight (54%) considered theatre pollution a problem in paediatric anaesthesia. One hundred and sixty-nine (57%) reported that in normal circumstances potential deleterious effects on patients influenced their use of nitrous oxide, whilst only 70 (24%) felt potential effects on staff influenced usage. Fifty-five (18%) felt there should be some restriction in the availability of nitrous oxide.
Item Type: | Article |
---|---|
Date Type: | Publication |
Status: | Published |
Schools: | Medicine |
Subjects: | R Medicine > R Medicine (General) R Medicine > RZ Other systems of medicine |
Publisher: | Wiley-Blackwell |
ISSN: | 0003-2409 |
Last Modified: | 28 Oct 2022 08:34 |
URI: | https://orca.cardiff.ac.uk/id/eprint/71257 |
Citation Data
Cited 10 times in Scopus. View in Scopus. Powered By Scopus® Data
Actions (repository staff only)
Edit Item |